2 VALVES VAL-264 For further information www.norgren.com Options C0021A/D Valves with tapped muffler base that accepts a muffler with 3/4" NPT male threads: Specify 1M2 after the desired valve model number. Recommended muffler: MB006A. C0022A/D Valves with tapped muffler base that accepts a muffler with 1" NPT male threads: Specify 1M1 after the desired valve model number. Recommended muffler MB008A. Note: Standard valves have a black handle. To order valves with a red handle, change the second position of the model number to an R (e.g., C0021A would change to CR021A). 3-way, manually operated, full flow loc- kout valves can be locked in the closed position with a customer supplied pad- lock. Helps you comply to OSHA regulations, as they relate to OSHA regulation 29 CFR Part 1910, standard for lockout/tagout procedures. Fluid: Compressed air, neutral gases NOTE: Contact Norgren for use with other media. Maximum Pressure: 300 psig (20.4 bar) Temperature Range: -20° to 175°F* (-29° to 79°C) *With a dew point of supply air less than air temperature below 35°F (2°C). Maximum Diameter of Lock Shackle: 5/16" (8mm) Materials Valve Body: Aluminum Muffler Base: Zinc Spool, T-Handle, Muffler Shell: Aluminum Spring Detent: Stainless Steel Elastomers Standard: Nitrile and Polyurethane Optional: Fluorocarbon Repair Kits C0021A/D and C0023A/D Valves: Standard Elastomers: 53474-43 Fluorocarbon Elastomers: 53474-44 C0022A/D and C0024A/D Valves: Standard Elastomers: 53475-34 Fluorocarbon Elastomers: 53475-36 Replacement Mufflers* for C0021A/C0024D Valves C0021A/D and C0023A/D Valves: ML004F C0022A/D and C0024A/D Valves: ML008F *Contains all bolts and washers required to flange mount with the respective sized lockout valve. Lockout Hasp Part Number: 54547-01 Note: The 1-1/2" diameter jaws can be used with all Norgren Inline, Olympian, and Poppet Lockout Valves except the T15. High-tensile steel affords extra protection against unauthorized access. Red vinyl coated and plated to resist rust. Locking holes accommodate pad- locks up to 11/32" shackle diameter. Technical data Ordering information Models listed are with PTF threads. Graphic symbol Basic Size Port Size PTF Model Without Muffler Model With Muffler Basic Size Port Size ISO G Model Without Muffler Model With Muffler In-Out Ports Out-Exhaust Ports 1/2" 1/4" C0021A C0023A 1/2" G1/4 C0041A C0043A 4.2 6.0 3/8" C0021B C0023B G3/8 C0041B C0043B 6.6 6.6 1/2" C0021C C0023C G1/2 C0041C C0043C 9.3 7.9 3/4" C0021D C0023D G3/4 C0041D C0043D 12.6 8.6 1" 3/4" C0022A C0024A 1" G3/4 C0042A C0044A 10.6 8. 1" C0022B C0024B G1 C0042B C0044B 16.2 9.2 1-1/4" C0022C C0024C G1-1/4 C0042C C0044C 25.3 8.9 1-1/2" C0022D C0024D – – – 22.4 10.0 Cv Factor IN OUT EXHAUST Inline Lockout Valves For installation in 1/4" through 1-1/2" air lines