VALVES 2 VAL-219 For further information www.norgren.com Prospector Series Poppet Valves 1/4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves Hazardous Version 3/2 Multi-directional solenoid to operate/spring return Internal pilot with locking override* Model Port Size Cv A to C port Cv A to B port Voltages** Operating Pressure* Pilot Pressure* Repair Kit C1012C-X1 1/4" PTF 2.50 2.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 C1012C-X11ND 1/4" PTF 2.50 2.00 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 C1013C-X1 3/8" PTF 4.00 2.70 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 C1013C-X11ND 3/8" PTF 4.00 2.70 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 C1014C-X1 1/2" PTF 5.70 3.40 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 C1014C-X11ND 1/2" PTF 5.70 3.40 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 C1025C-X1 3/4" PTF 6.10 4.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 C1025C-X11ND 3/4" PTF 6.10 4.00 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 C1035C-X1 3/4" PTF 14.80 10.30 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 C1035C-X11ND 3/4" PTF 14.80 10.30 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 C1036C-X1 1" PTF 17.70 13.20 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 C1036C-X11ND 1" PTF 17.70 13.20 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 C1037C-X1 1-1/4" PTF 18.30 14.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 C1037C-X11ND 1-1/4" PTF 18.30 14.00 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 C1048C-X1 1-1/2" PTF 44.80 33.10 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01 C1048C-X11ND 1-1/2" PTF 44.80 33.10 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01 C1049C-X1 2" PTF 49.50 40.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01 C1049C-X11ND 2" PTF 49.50 40.00 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01 * For No override replace the -X1 with a -X0. ** External pilot service replace the 6 digit "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external pilot supply. BSPP threads replace the 2 digit "1" with an "A". NOTE: If used as normally open valve, an external pilot supply is required. OUT2 OUT1 A IN B C Distributor IN2 IN1 OUT A B C Selector EXH IN OUT A C B Normally Closed EXH IN OUT A B C Normally Open

Articles in this issue

Links on this page

Archives of this issue

view archives of Pneumatic & Fluid Control Catalog - z7424CT - 02 - IMI Norgren Valves Solenoid & Air Pilot