VALVES
2
VAL-219
For further information www.norgren.com
Prospector Series Poppet Valves
1/4" to 2" Solenoid Pilot Actuated
2/2, 3/2, & 4/2 Inline Valves
Hazardous Version
3/2 Multi-directional solenoid to operate/spring return
Internal pilot with locking override*
Model Port Size Cv A to C port Cv A to B port Voltages** Operating Pressure* Pilot Pressure* Repair Kit
C1012C-X1 1/4" PTF 2.50 2.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
C1012C-X11ND 1/4" PTF 2.50 2.00 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
C1013C-X1 3/8" PTF 4.00 2.70 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
C1013C-X11ND 3/8" PTF 4.00 2.70 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
C1014C-X1 1/2" PTF 5.70 3.40 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
C1014C-X11ND 1/2" PTF 5.70 3.40 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
C1025C-X1 3/4" PTF 6.10 4.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
C1025C-X11ND 3/4" PTF 6.10 4.00 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
C1035C-X1 3/4" PTF 14.80 10.30 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01
C1035C-X11ND 3/4" PTF 14.80 10.30 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01
C1036C-X1 1" PTF 17.70 13.20 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01
C1036C-X11ND 1" PTF 17.70 13.20 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01
C1037C-X1 1-1/4" PTF 18.30 14.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01
C1037C-X11ND 1-1/4" PTF 18.30 14.00 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01
C1048C-X1 1-1/2" PTF 44.80 33.10 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01
C1048C-X11ND 1-1/2" PTF 44.80 33.10 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01
C1049C-X1 2" PTF 49.50 40.00 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01
C1049C-X11ND 2" PTF 49.50 40.00 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01
* For No override replace the -X1 with a -X0.
** External pilot service replace the 6 digit "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external
pilot supply.
BSPP threads replace the 2 digit "1" with an "A".
NOTE: If used as normally open valve, an external pilot supply is required.
OUT2 OUT1
A
IN
B C
Distributor
IN2 IN1
OUT
A
B C
Selector
EXH IN
OUT
A
C B
Normally Closed
EXH IN
OUT
A
B C
Normally Open