Issue link: https://onenorgren.uberflip.com/i/553538
2 VALVES VAL-216 For further information www.norgren.com Prospector Series Poppet Valves 1/4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves Connector Description Connector Code Order Separately Cable Grip 0 -240VDC/VAC standard 54934-01 1/2" conduit 0 -240VDC/VAC 1V3 54934-05 Cable Grip with LED 24 VDC/VAC 1V4 54934-08 Cable Grip with LED 120VAC 1VB 54934-02 6' Molded cable 0-240VDC/VAC 1V5 54934-21 Examples: C1014C-CF1WH with a Cable Grip Connector, change to Cable Grip with LED option, order C1014C-CF1W21VB C1036C-CF with a Cable Grip Connector, changed to a 6' molded cable option, order C1036C-CF1V5 Note: Additional connectors add the code from table below to the end of the part number Voltage Description Volatge Code Order Separately 12 VDC 1WF 54469-01 24 VDC standard 54469-02 24V 50/60 Hz 1UD 54469-04 120V 50/60 Hz 1WH 54469-03 220/240V, 50/60 Hz 1WN 54469-08 Examples: C1012C-CF 24 VDC, changed to a 12 VDC option, order C1012C-CF1WF C1025H-CF1WH 120Vac, change to a 220/240V, 50/60Hz option, order C1025H-CF1WN Note: Additional voltages,add or replace the 1WA in above code with the voltage code from table below in the desired part number Low Wattage Version 3/2 Multi-directional solenoid to operate/spring return Internal pilot with locking override* and cable grip connector** Model Port Size Cv A to C port Cv A to B port Voltages** Operating Pressure* Pilot Pressure* Repair Kit C1012C-CF 1/4" PTF 2.50 2.00 24 VDC 2W 30-150 psig 30-150 psig 53474-03 C1012C-CF1WH 1/4" PTF 2.50 2.00 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 C1013C-CF 3/8" PTF 4.00 2.70 24 VDC 2W 30-150 psig 30-150 psig 53474-03 C1013C-CF1WH 3/8" PTF 4.00 2.70 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 C1014C-CF 1/2" PTF 5.70 3.40 24 VDC 2W 30-150 psig 30-150 psig 53474-03 C1014C-CF1WH 1/2" PTF 5.70 3.40 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 C1025C-CF 3/4" PTF 6.10 4.00 24 VDC 2W 30-150 psig 30-150 psig 53474-03 C1025C-CF1WH 3/4" PTF 6.10 4.00 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 C1035C-CF 3/4" PTF 14.80 10.30 24 VDC 2W 30-150 psig 30-150 psig 53475-01 C1035C-CF1WH 3/4" PTF 14.80 10.30 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53475-01 C1036C-CF 1" PTF 17.70 13.20 24 VDC 2W 30-150 psig 30-150 psig 53475-01 C1036C-CF1WH 1" PTF 17.70 13.20 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53475-01 C1037C-CF 1-1/4" PTF 18.30 14.00 24 VDC 2W 30-150 psig 30-150 psig 53475-01 C1037C-CF1WH 1-1/4" PTF 18.30 14.00 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53475-01 C1048C-CF 1-1/2" PTF 44.80 33.10 24 VDC 2W 30-150 psig 30-150 psig 53822-01 C1048C-CF1WH 1-1/2" PTF 44.80 33.10 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53822-01 C1049C-CF 2" PTF 49.50 40.00 24 VDC 2W 30-150 psig 30-150 psig 53822-01 C1049C-CF1WH 2" PTF 49.50 40.00 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53822-01 * External pilot service replace the 6 digit "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external pilot supply. ** Additional voltages and connector option refer to below tables. BSPP threads replace the 2 digit "1" with an "A". NOTE: If used as normally open valve, an external pilot supply is required. OUT2 OUT1 A IN B C Distributor IN2 IN1 OUT A B C Selector EXH IN OUT A C B Normally Closed EXH IN OUT A B C Normally Open