Pneumatic & Fluid Control Catalog - z7424CT

02 - IMI Norgren Valves Solenoid & Air Pilot

Issue link: https://onenorgren.uberflip.com/i/553538

Contents of this Issue

Navigation

Page 76 of 97

2 VALVES VAL-212 For further information www.norgren.com Prospector Series Poppet Valves 1/4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves Hazardous Version 3/2 Normally Closed solenoid to operate/spring return Internal pilot with locking override* Model Port Size Cv In to Out port Cv Out to Exh port Voltages*** Operating Pressure** Pilot Pressure** Repair Kit D1012B-X1 1/4" PTF 1.5 1.8 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53473-05 D1012B-X11ND 1/4" PTF 1.5 1.8 24 VDC 9.5W 30-150 psig 30-150 psig 53473-05 D1013B-X1 3/8" PTF 1.7 1.8 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53473-05 D1013B-X11ND 3/8" PTF 1.7 1.8 24 VDC 9.5W 30-150 psig 30-150 psig 53473-05 D1022C-X1 1/4" PTF 2.7 3.9 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 D1022C-X11ND 1/4" PTF 2.7 3.9 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 D1023C-X1 3/8" PTF 3.6 4.9 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 D1023C-X11ND 3/8" PTF 3.6 4.9 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 D1024C-X1 1/2" PTF 4.6 5.8 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 D1024C-X11ND 1/2" PTF 4.6 5.8 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 D1025C-X1 3/4" PTF 5.4 6.2 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 D1025C-X11ND 3/4" PTF 5.4 6.2 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 D1035C-X1 3/4" PTF 11.2 13.3 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 D1035C-X11ND 3/4" PTF 11.2 13.3 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 D1036C-X1 1" PTF 13.2 14.6 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 D1036C-X11ND 1" PTF 13.2 14.6 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 D1047C-X1 1-1/4" PTF 16.6 18.4 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 D1047C-X11ND 1-1/4" PTF 16.6 18.4 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 * For No override replace the -X1 with a -X0. ** Vacuum service replace the 6 digit "B" or "C" with a "J", this will then allow the operating pressure down to 29" Hg, with a pilot pressure of 30-150 psig. ** External pilot service replace the 6 digit "B" or "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external pilot supply. BSPP threads replace the 2 digit "1" with an "A". EXH IN OUT Normally Closed

Articles in this issue

Links on this page

Archives of this issue

view archives of Pneumatic & Fluid Control Catalog - z7424CT - 02 - IMI Norgren Valves Solenoid & Air Pilot