Issue link: https://onenorgren.uberflip.com/i/553538
VALVES 2 VAL-209 For further information www.norgren.com Prospector Series Poppet Valves 1/4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves Connector Description Connector Code Order Separately Cable Grip 0 -240VDC/VAC standard 54934-01 1/2" conduit 0 -240VDC/VAC 1V3 54934-05 Cable Grip with LED 24 VDC/VAC 1V4 54934-08 Cable Grip with LED 120VAC 1VB 54934-02 6' Molded cable 0-240VDC/VAC 1V5 54934-21 Examples: D1024C-CF1WH with a Cable Grip Connector, change to Cable Grip with LED option, order D1024C-CF1W21VB D1036C-CF with a Cable Grip Connector, changed to a 6' molded cable option, order D1036C-CF1V5 Note: Additional connectors add the code from table below to the end of the part number Voltage Description Volatge Code Order Separately 12 VDC 1WF 54469-01 24 VDC standard 54469-02 24V 50/60 Hz 1UD 54469-04 120V 50/60 Hz 1WH 54469-03 220/240V, 50/60 Hz 1WN 54469-08 Examples: D1012B-CF 24 VDC, changed to a 12 VDC option, order D1012B-CF1WF D1025H-CF1WH 120Vac, change to a 220/240V, 50/60Hz option, order D1025H-CF1WN Note: Additional voltages,add or replace the 1WH in above code with the voltage code from table below in the desired part number Low Wattage Version 3/2 Normally Closed solenoid to operate/spring return Internal pilot with locking override* and cable grip connector*** Model Port Size Cv In to Out port Cv Out to Exh port Voltages*** Operating Pressure** Pilot Pressure** Repair Kit D1012B-CF 1/4" PTF 1.5 1.8 24 VDC 2W 30-150 psig 30-150 psig 53473-05 D1012B-CF1WH 1/4" PTF 1.5 1.8 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53473-05 D1013B-CF 3/8" PTF 1.7 1.8 24 VDC 2W 30-150 psig 30-150 psig 53473-05 D1013B-CF1WH 3/8" PTF 1.7 1.8 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53473-05 D1022C-CF 1/4" PTF 2.7 3.9 24 VDC 2W 30-150 psig 30-150 psig 53474-03 D1022C-CF1WH 1/4" PTF 2.7 3.9 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 D1023C-CF 3/8" PTF 3.6 4.9 24 VDC 2W 30-150 psig 30-150 psig 53474-03 D1023C-CF1WH 3/8" PTF 3.6 4.9 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 D1024C-CF 1/2" PTF 4.6 5.8 24 VDC 2W 30-150 psig 30-150 psig 53474-03 D1024C-CF1WH 1/2" PTF 4.6 5.8 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 D1025C-CF 3/4" PTF 5.4 6.2 24 VDC 2W 30-150 psig 30-150 psig 53474-03 D1025C-CF1WH 3/4" PTF 5.4 6.2 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53474-03 D1035C-CF 3/4" PTF 11.2 13.3 24 VDC 2W 30-150 psig 30-150 psig 53475-01 D1035C-CF1WH 3/4" PTF 11.2 13.3 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53475-01 D1036C-CF 1" PTF 13.2 14.6 24 VDC 2W 30-150 psig 30-150 psig 53475-01 D1036C-CF1WH 1" PTF 13.2 14.6 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53475-01 D1047C-CF 1-1/4" PTF 16.6 18.4 24 VDC 2W 30-150 psig 30-150 psig 53475-01 D1047C-CF1WH 1-1/4" PTF 16.6 18.4 120 VAC 60 Hz 3.5W 30-150 psig 30-150 psig 53475-01 * For Non-locking override replace the -CF with a -CZ. ** Vacuum service replace the 6 digit "B" or "C" with a "J", this will then allow the operating pressure down to 29" Hg, with a pilot pressure of 30-150 psig. ** External pilot service replace the 6 digit "B" or "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external pilot supply. *** Additional voltages and connector option refer to below tables. BSPP threads replace the 2 digit "1" with an "A". EXH IN OUT Normally Closed