Pneumatic & Fluid Control Catalog - z7424CT

02 - IMI Norgren Valves Solenoid & Air Pilot

Issue link: https://onenorgren.uberflip.com/i/553538

Contents of this Issue

Navigation

Page 68 of 97

2 VALVES VAL-204 For further information www.norgren.com Prospector Series Poppet Valves 1/4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves Hazardous Location Versions 2/2 Normally Closed solenoid to operate/spring return Internal pilot with Locking Override* Model Port Size Cv Port A to B Override Voltages*** Operating Pressure** Pilot Pressure** Repair Kit A1012C-X1 1/4" PTF 2.1 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 A1012C-X11ND 1/4" PTF 2.1 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 A1013C-X1 3/8" PTF 3.4 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 A1013C-X11ND 3/8" PTF 3.4 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 A1014C-X1 1/2" PTF 5.3 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 A1014C-X11ND 1/2" PTF 5.3 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 A1015C-X1 3/4" PTF 6.5 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03 A1015C-X11ND 3/4" PTF 6.5 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03 A1025C-X1 3/4" PTF 10.7 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 A1025C-X11ND 3/4" PTF 10.7 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 A1026C-X1 1" PTF 13.5 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 A1026C-X11ND 1" PTF 13.5 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 A1027C-X1 1-1/4" PTF 16.3 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01 A1027C-X11ND 1-1/4" PTF 16.3 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01 A1038C-X1 1-1/2" PTF 34 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01 A1038C-X11ND 1-1/2" PTF 34 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01 A1039C-X1 2" PTF 39.6 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01 A1039C-X11ND 2" PTF 39.6 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01 * For No override replace the -X1 with a -X0. ** Vacuum service replace the 6 digit "C" with a "J", this will then allow the operating pressure down to 29" Hg, with a pilot pressure of 30-150 psig. ** External pilot service replace the 6 digit "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external pilot supply. BSPP threads replace the 2 digit "1" with an "A". OUT B A IN Normally Closed

Articles in this issue

Links on this page

Archives of this issue

view archives of Pneumatic & Fluid Control Catalog - z7424CT - 02 - IMI Norgren Valves Solenoid & Air Pilot