2
VALVES
VAL-186
For further information www.norgren.com
Long lasting spool design
High flow compact valves
Three functional types: available in 3/2, 5/2,
and 5/3 configurations
Low pressure operators
Technical data
Medium:
Filtered and lubricated or non-
lubricated compressed air or
vacuum.
Operation:
Spool valve air pilot actuated.
Mounting:
Inline – through holes in valve body.
Port Size:
NPT – 1/4", 3/8", 1/2"
ISO G – 1/4", 3/8" .
Operating Pressure:
10 Hg vacuum to 150 psig (10.3
bar). For details see overleaf.
Operating Temperature:
-20° to 160°F (-29° to 71°C)
Consult Technical Service for use
below 35°F (2°C).
Materials:
Body: Aluminum
Spool: Anodized aluminum
Elastomers: Nitrile and special
nitrile based low-friction
elastomers.
Minimum Pilot Pressures
Operator Return Nondetent
psig (bar)
Detented
psig (bar)
Spring Centered
psig (bar)
Large Air Large Air 15 (1.0) 25 (1.7) 45 (3.1)
Large Air † Small Air 35 (2.4) – –
Small Air Small Air 25 (1.7) – –
Large Air Spring 35 (2.4) – –
Low Pressure
Air††
Spring 4 (.27) – –
Small Air Spring 65 (4.5) – –
Air Bleed Air Bleed 15 (1.0) 25 (1.7) –
Air Bleed Spring 35 (2.4) – –
† Pressure applied simultaneously to both operators. The piston area of the KA2
operator is approximately twice that of the KA1 operator.
†† Pressure applied to port B of KA6 operator (port A open). A minimum vacuum
of 6.1 inches Hg (KS1 return) applied to A (port B open) will also operate the valve.
The KA6 operator can also be used as a differential pressure operator with or without
return spring. The differential pressure required to shift the valve without return spring
is less than 1 psig (2" Hg). To reduce the possibility of internal contamination, it is
suggested that a filter/breather be installed in the port.
Average Flow Factors in Cv‡ (l/min)
Valve Port
Size
Flow Path
Port
1 to 2
1 to 4
Port
2 to 3
4 to 5
3-Port, Inline 1/4" 1.6 (1600) 1.7 (1700)
3/8" 1.6 (1600) 1.7 (1700)
5-Port, Inline 1/4" 1.6 (1600) 1.7 (1700)
3/8" 1.6 (1600) 1.7 (1700)
1/2" 1.6 (1600) 1.7 (1700)
‡ Flow Rating determined in accordance with NFPA/T3.21.3, Pneumatic fluid power –
Flow test procedure and reporting method – For fixed orifice components.
Nugget 200 Spool Valves
1/4", 3/8", 1/2" NPT Air Pilot Actuated
3/2, 5/2, & 5/3 Inline Valves