2
VALVES
VAL-204
For further information www.norgren.com
Prospector Series Poppet Valves
1/4" to 2" Solenoid Pilot Actuated
2/2, 3/2, & 4/2 Inline Valves
Hazardous Location Versions
2/2 Normally Closed solenoid to operate/spring return
Internal pilot with Locking Override*
Model Port Size Cv Port A to B Override Voltages*** Operating Pressure** Pilot Pressure** Repair Kit
A1012C-X1 1/4" PTF 2.1 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
A1012C-X11ND 1/4" PTF 2.1 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
A1013C-X1 3/8" PTF 3.4 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
A1013C-X11ND 3/8" PTF 3.4 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
A1014C-X1 1/2" PTF 5.3 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
A1014C-X11ND 1/2" PTF 5.3 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
A1015C-X1 3/4" PTF 6.5 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53474-03
A1015C-X11ND 3/4" PTF 6.5 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53474-03
A1025C-X1 3/4" PTF 10.7 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01
A1025C-X11ND 3/4" PTF 10.7 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01
A1026C-X1 1" PTF 13.5 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01
A1026C-X11ND 1" PTF 13.5 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01
A1027C-X1 1-1/4" PTF 16.3 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53475-01
A1027C-X11ND 1-1/4" PTF 16.3 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53475-01
A1038C-X1 1-1/2" PTF 34 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01
A1038C-X11ND 1-1/2" PTF 34 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01
A1039C-X1 2" PTF 39.6 Locking 120 VAC 60 Hz 12W 30-150 psig 30-150 psig 53822-01
A1039C-X11ND 2" PTF 39.6 Locking 24 VDC 9.5W 30-150 psig 30-150 psig 53822-01
* For No override replace the -X1 with a -X0.
** Vacuum service replace the 6 digit "C" with a "J", this will then allow the operating pressure down to 29" Hg, with a pilot pressure of 30-150 psig.
** External pilot service replace the 6 digit "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external
pilot supply.
BSPP threads replace the 2 digit "1" with an "A".
OUT
B
A
IN
Normally Closed