2 VALVES VAL-202 For further information www.norgren.com Prospector Series Poppet Valves 1/4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves Standard Wattage Version 2/2 Normally Closed solenoid to operate/spring return Internal pilot with locking override* and cable grip connector*** Model Port Size Cv Port A to B Voltages*** Operating Pressure** Pilot Pressure** Repair Kit A1012C-CE 1/4" PTF 2.1 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53474-03 A1012C-CE1W2 1/4" PTF 2.1 24 VDC 6W 30-150 psig 30-150 psig 53474-03 A1013C-CE 3/8" PTF 3.4 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53474-03 A1013C-CE1W2 3/8" PTF 3.4 24 VDC 6W 30-150 psig 30-150 psig 53474-03 A1014C-CE 1/2" PTF 5.3 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53474-03 A1014C-CE1W2 1/2" PTF 5.3 24 VDC 6W 30-150 psig 30-150 psig 53474-03 A1015C-CE 3/4" PTF 6.5 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53474-03 A1015C-CE1W2 3/4" PTF 6.5 24 VDC 6W 30-150 psig 30-150 psig 53474-03 A1025C-CE 3/4" PTF 10.7 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53475-01 A1025C-CE1W2 3/4" PTF 10.7 24 VDC 6W 30-150 psig 30-150 psig 53475-01 A1026C-CE 1" PTF 13.5 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53475-01 A1026C-CE1W2 1" PTF 13.5 24 VDC 6W 30-150 psig 30-150 psig 53475-01 A1027C-CE 1-1/4" PTF 16.3 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53475-01 A1027C-CE1W2 1-1/4" PTF 16.3 24 VDC 6W 30-150 psig 30-150 psig 53475-01 A1038C-CE 1-1/2" PTF 34 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53822-01 A1038C-CE1W2 1-1/2" PTF 34 24 VDC 6W 30-150 psig 30-150 psig 53822-01 A1039C-CE 2" PTF 39.6 120 VAC 60 Hz 7W 30-150 psig 30-150 psig 53822-01 A1039C-CE1W2 2" PTF 39.6 24 VDC 6W 30-150 psig 30-150 psig 53822-01 * For Non-locking override replace the -CE with a -CY ** Vacuum service replace the 6 digit "C" with a "J", this will then allow the operating pressure down to 29" Hg, with a pilot pressure of 30-150 psig ** External pilot service replace the 6 digit "C" with a "H", operating pressure will now go to 0, but a minimum of 30 psig and/or greater than supply pressure, required for external pilot supply *** Additional voltages and connector option refer to below tables BSPP threads replace the 2 digit "1" with an "A" Connector Description Connector Code Order Separately Cable Grip 0 -240VDC/VAC standard 54934-01 1/2" conduit 0 -240VDC/VAC 1V3 54934-05 Cable Grip with LED 24 VDC/VAC 1V4 54934-08 Cable Grip with LED 120VAC 1VB 54934-02 6' Molded cable 0-240VDC/VAC 1V5 54934-21 Examples: A1027C-CE1W2 with a Cable Grip Connector, change to Cable Grip with LED option, order A1027C-CE1W21V4 A1039C-CE with a Cable Grip Connector, changed to a 6' molded cable option, order A1039C-CE1V5 Note: Additional connectors add the code from table below to the end of the part number Voltage Description Volatge Code Order Separately 12 VDC 1W1 54452-02 24 VDC 1W2 54452-03 24V 50/60 Hz 1W4 54452-05 220V 50/60 Hz standard 54452-01 220/240V, 50/60 Hz 1W6 54452-07 Examples: A1012C-CE 120VAC, changed to a 12 VDC option, order A1012C-CE1W1 A1025H-CE1W2 24 VDC, change to a 220/240V, 50/60Hz option, order A1025H-CE1W6 Note: Additional voltages,add or replace the 1W2 in above code with the voltage code from table below in the desired part number OUT B A IN Normally Closed