Issue link: https://onenorgren.uberflip.com/i/553520
2 VALVES VAL-52 For further information www.norgren.com Table 1 **Voltage Codes and Spare Pilot Valves Other voltages available on request. Spare pilot valves are delivered with mounting screws. Table 2 †Connector Codes and Part Number 5/2 Single and Double Solenoid Valve functions designations NO = Normally open NC = Normally closed COE = Cylinder Open Exhaust COP = Cylinder Open Pressure Non-plug-in solenoid pilot actuated valves 2x3/2 Double Solenoid, NC/NC, NO/NO, or NC/NO Model Spool technology Function 2 x 3/2 Actuation Cv Pilot supply Pilot pressure psi Operating pressure psi (bar) Manual override Voltage VS45SA11DC3**† Softseal NC or COE Sol/Spring 3.9 Internal - 44 to 145 (3 to 10) Push only 24 VDC 1.2W VS45SA11DC2**† Softseal NC or COE Sol/Spring 3.9 Internal - 44 to 145 (3 to 10) Push & turn 24 VDC 1.2W VS45SA22DC3**† Softseal NC or COE Sol/Spring 3.9 External 25 + (0.6 x op. press.) 0 to 145 (0 to 10) Push only 24 VDC 1.2W VS45SA22DC2**† Softseal NC or COE Sol/Spring 3.9 External 25 + (0.6 x op. press.) 0 to 145 (0 to 10) Push & turn 24 VDC 1.2W VS45SB11DC3**† Softseal NO or COP Sol/Spring 3.9 Internal - 44 to 145 (3 to 10) Push only 24 VDC 1.2W VS45SB11DC2**† Softseal NO or COP Sol/Spring 3.9 Internal - 44 to 145 (3 to 10) Push & turn 24 VDC 1.2W VS45SB22DC3**† Softseal NO or COP Sol/Spring 3.9 External 25 + (0.6 x op. press.) 0 to 145 (0 to 10) Push only 24 VDC 1.2W VS45SB22DC2**† Softseal NO or COP Sol/Spring 3.9 External 25 + (0.6 x op. press.) 0 to 145 (0 to 10) Push & turn 24 VDC 1.2W VS45SC11DC3**† Softseal NO/NC Sol/Spring 3.9 Internal - 44 to 145 (3 to 10) Push only 24 VDC 1.2W VS45SC11DC2**† Softseal NO/NC Sol/Spring 3.9 Internal - 44 to 145 (3 to 10) Push & turn 24 VDC 1.2W VS45SC22DC3**† Softseal NO/NC Sol/Spring 3.9 External 25 + (0.6 x op. press.) 0 to 145 (0 to 10) Push only 24 VDC 1.2W VS45SC22DC2**† Softseal NO/NC Sol/Spring 3.9 External 25 + (0.6 x op. press.) 0 to 145 (0 to 10) Push & turn 24 VDC 1.2W Model Spool technology Function Actuation Cv Pilot supply Pilot pressure psi (bar) Operating pressure psi (bar) Manual override Voltage VS45G511DC3**† Glandless 5/2 Sol/Sol 3.2 Internal - 29 to 145 (2 to 10) Push only 24 VDC 1.2W VS45G511DC2**† Glandless 5/2 Sol/Sol 3.2 Internal - 29 to 145 (2 to 10) Push & turn 24 VDC 1.2W VS45G522DC3**† Glandless 5/2 Sol/Sol 3.2 External 29 to 145 (2 to 10) 26" Hg to 232 (-0.9 to 16) Push only 24 VDC 1.2W VS45G522DC2**† Glandless 5/2 Sol/Sol 3.2 External 29 to 145 (2 to 10) 26" Hg to 232 (-0.9 to 16) Push & turn 24 VDC 1.2W VS45G517DC3**† Glandless 5/2 Sol/Spring 3.2 Internal - 29 to 145 (2 to 10) Push only 24 VDC 1.2W VS45G517DC2**† Glandless 5/2 Sol/Spring 3.2 Internal - 29 to 145 (2 to 10) Push & turn 24 VDC 1.2W VS45G527DC3**† Glandless 5/2 Sol/Spring 3.2 External 29 to 145 (2 to 10) 26" Hg to 232 (-0.9 to 16) Push only 24 VDC 1.2W VS45G527DC2**† Glandless 5/2 Sol/Spring 3.2 External 29 to 145 (2 to 10) 26" Hg to 232 (-0.9 to 16) Push & turn 24 VDC 1.2W VS45S511DC3**† Softseal 5/2 Sol/Sol 4.2 Internal - 29 to 145 (2 to 10) Push only 24 VDC 1.2W VS45S511DC2**† Softseal 5/2 Sol/Sol 4.2 Internal - 29 to 145 (2 to 10) Push & turn 24 VDC 1.2W VS45S522DC3**† Softseal 5/2 Sol/Sol 4.2 External 29 to 145 (2 to 10) 26" Hg to 145 (-0.9 to 10) Push only 24 VDC 1.2W VS45S522DC2**† Softseal 5/2 Sol/Sol 4.2 External 29 to 145 (2 to 10) 26" Hg to 145 (-0.9 to 10) Push & turn 24 VDC 1.2W VS45S517DC3**† Softseal 5/2 Sol/Spring 4.2 Internal - 29 to 145 (2 to 10) Push only 24 VDC 1.2W VS45S517DC2**† Softseal 5/2 Sol/Spring 4.2 Internal - 29 to 145 (2 to 10) Push & turn 24 VDC 1.2W VS45S527DC3**† Softseal 5/2 Sol/Spring 4.2 External 29 to 145 (2 to 10) 26" Hg to 145 (-0.9 to 10) Push only 24 VDC 1.2W VS45S527DC2**† Softseal 5/2 Sol/Spring 4.2 External 29 to 145 (2 to 10) 26" Hg to 145 (-0.9 to 10) Push & turn 24 VDC 1.2W Code Part Number A = Solenoid without connector B = Cable grip V10027-D00 C = 10 ft. molded cable, 0-240 VAC/VDC V10013-D03 H = Cable grip w/indicator light, 24 VAC/VDC V10012-D13 J = Cable grip w/indicator light, 120 VAC/VDC V10012-D18 5 = 10 ft. molded cable with indicator light, surge suppression, 24 VAC/VDC V10014-D03 6 = 10 ft. molded cable with indicator light, 110V/50 Hz-120V.60Hz V10015-D03 Voltage Code Manual Override Power Inrush / Hold Pilot Valve Part.-no. 24 VDC 13 Push & turn 1.2W VS45DC213-KG00 115 V 50/60 Hz 18 Push & turn 2.1 / 1.5 VA VS45DC218-KG00 24 VDC 13 Push only 1.2W VS45DC313-KG00 115 V 50/60 Hz 18 Push only 2.1 / 1.5 VA VS45DC318-KG00 Valve Manifolds VS45 Series 2x3/2, 5/2 and 5/3 valves Size 45 mm 5 1 12/14 3 4 2 10 10 14 12 5 1 3 4 2 14 12 10 10 5 1 3 4 2 10 12 14 10 5 1 12/14 3 4 2 14 12 10 10 5 1 12/14 3 4 2 10 12 14 10 5 1 3 4 2 10 10 14 12 4 2 14 12 3 5 1 4 2 14 12 12/14 3 5 1 4 2 14 12 3 5 1 4 2 14 12 3 5 1 12/14 4 2 14 12 3 5 1 4 2 14 12 12/14 3 5 1 4 2 14 12 3 5 1 4 2 14 12 3 5 1 12/14