VALVES
2
VAL-21
For further information www.norgren.com
2.32
(59)
0.79
(20)
0.83
(21)
0.85
(21.5)
M
12
M
12
1
4
3
2
1
4
3
2
1.97
(50)
0.94
(24)
0.85
(21.5)
0.79
(20)
M12
M12
1
4
3
2
1
4
3
2
1
2
3
4
Male
3
1
5
2 4
Male
Communication in
1
2
3
4
Male
3
1
5
2 4
Male
Communication
in
Dimensions in inches (mm)
Fieldbus protocol: DeviceNet
Connector: 1 x M12 5-pin / M12 4-pin Bus connector: M12 5-pin (A-coded)
Pin no. Function
1 Drain
2 V+
3
3 V-
3
4 CAN_H
5 CAN_L
Power connector: M12 4-pin
Pin no. Function Tolerance Max current
1 24 VB logic circuit supply +/-25% 300 mA
2 24 VA valves +/-10% 1)
3 0 volts – 2)
4 Earth – -
Fieldbus protocol: CANopen
Connector: 1 x M12 5-pin / M12 4-pin
Bus connector: M12 5-pin (A-coded)
Pin no. Function
1 Drain
2 V+
3
3 V-
3
4 CAN_H
5 CAN_L
Power connector: M12 4-pin
Pin no. Function Tolerance Max current
1 24 VB logic circuit supply +/-25% 300 mA
2 24 VA valves +/-10% 1)
3 0 volts – 2)
4 Earth – –
1)
I
max = 10 mA + n*60 mA
n = number of energized solenoids
2)
I
max =
I
VA +
I
VB
3) Must be galvanic isolated to 24 VA valves.
Valve Manifolds VS18 Series
Plug-in Mini ISO Valves
2x2/2, 2x3/2, 5/2 and 5/3 valves, ISO 15407-2, Size 18 mm