VALVES
2
VAL-121
For further information www.norgren.com
Note:
5/3 COE please use 2 x 3/2 NC
5/3 COP please use 2 x 3/2 NO
NC = Normally Closed
NO = Normally Open
APB = All Ports Blocked
COE = Center Open Exhaust
COP = Center Open Pressure
Use our configurator at www.norgren.com/usa
Valve manifolds VM15 Series
Valve slices 2x3/2, 5/2 and 5/3 with integral push-in fittings
Ø 1/4", 5/16", 3/8", 6, 8, and 10 mm
Multipole or individually wired for installation flexibility
Compact and lightweight
Quick disconnect base (Pneumapole)
High flow from a (15 mm) valve width
Flexible design concept
Integral push in fittings
Technical data
Medium:
Compressed air, filtered to 40 µm,
lubricated or non-lubricated
Operation:
Spool valve indirectly actuated
Port sizes:
Ø 1/4", 5/16" and 3/8" (6 mm,
8 mm and 10 mm) push-in fittings
Tube types:
Nylon 11 or 12, polyurethane* and
other plasticized or unplasticised
tubing conforming to the tolerances
specified in DIN 73378. NFE
49-101. ISO/WD 16026
Operating pressure:
116 psig (8 bar) max.
Ambient temperature:
23°F to 122°F (-5°C to 50°C)
Air supply must be dry enough
to avoid ice formation at
temperatures below 36°F (2°C).
Flow:
Function Cv l/min
5/2 1.01 1.000
2 x 3/2 0.97 965
5/3 0.91 900
Degree of protection:
Individually wired IP40
Multipole IP65
Fieldbus IP65
Materials
Body, end plates: engineered PPA
co-polymer
Spool: aluminum
Seals: NBR
Options selector
Tube size Substitute
1/4" PIF 1
5/16" PIF 5
3/8" PIF 2
6 mm PIF 6
8 mm PIF 8
10 mm PIF Y
No PIF (for Pneumapole) 7
Valve function Substitute
5/2 5
5/3 APB 6
2 x 3/2 NC and 5/3 COE A
2 x 3/2 NO and 5/3 COP B
2 x 3/2 NC and NO C
Manual override Substitute
Push and turn to lock 2
Push only 3
Actuation/pilot supply Substitute
Solenoid/solenoid (internal pilot) 11
Solenoid/spring (internal pilot) 17
Solenoid/solenoid (external pilot) 22
Solenoid/spring (external pilot) 27
VM15HHHHABH13B