2
VALVES
VAL-54
For further information www.norgren.com
Valve part number breakdown
Electrical details for solenoid operators
VS45
HHHHHHHHH
A
Spool technology Substitute
Glandless spool & sleeve G
Softseal spool S
Guiding systems Substitute
2x3/2 Normally closed or Cylinder Open
Exhaust
A*
2x3/2 Normally open or Cylinder Open
Pressure
B*
2x3/2 Normally open/Normally closed C*
5/2 5
5/3 All ports blocked 6
5/3 Cylinder open exhaust 7**
* Available with softseal spool only
** Available with glandless spool only
Voltage Substitute
110/120 VAC 18
24 VDC 1.2W 13
Air pilot 00
Manual override Substitute
Push & turn
†
2
Push only
†
3
Extended, push only
†
5
Air pilot 5/32 PIF 9
Connection Substitute
Plug in DF
Non Plug-in DC
Non plug-in air pilot AX
Actuation/Pilot supply Substitute
Solenoid/Spring Internal pilot supply 17
Solenoid/Spring External pilot supply 27
Solenoid/Solenoid Internal pilot supply 11
Solenoid/Solenoid External pilot supply 22
Air/Spring D7
Air/Air DD
†Available with plug-in valves only
Voltage tolerances (24 VDC) +/- 10%
Rating 100 % Continous duty
Inlet orifice 0.8 mm
Indication LED green
Surge surpression Transil diode
Materials PPS (body), FPM and NBR (seal)
Protection classification (IP Code)
All VS45 valve manifolds fulfill IP65 and NEMA4 ratings.
Power supply and precautions
AII VS45 24 V d.c products are designed to be used with a protective extra
low voltage (PELV) power supply.
All VS45 115 V a.c products correspond to the protection class I.
Connection of the protective earth (PE) ground is required.
Valve Manifolds VS45 Series
2x3/2, 5/2 and 5/3 valves
Size 45 mm