94
5
ANCILLARY
PRODUCTS
For further information www.norgren.com/us
Medium:
Lubricated or non-lubricated
compressed air, inert gases
Operation:
The non-return function protects the
spring chamber of pneumatic actuators
in particular against aggressive ambient
air
Operating pressure:
10 bar max. (145 psi)
Operating temperature:
-55 ... +80°C (-67 ... +176°F)
Air supply must be dry enough to avoid ice formation
at temperatures below +2°C (+35°F).
Materials:
Housing: POM
'O'-rings: VMQ
Technical features
Models
Symbol Model Thread Suitable for
0613422000000000 1/4" G1/4, 1/4 NPT
0613423000000000 1/2" G1/2, 1/2 NPT
0613422, 0613423
Exhaust guard
1/4" & 1/2"
Protects against
contamination
and moisture
penetration
universal
thread
BSP/NPT