Issue link: https://onenorgren.uberflip.com/i/552086
42 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 V-22O-E-F V-22O-EH-F V-22O-ER-F For further information www.norgren.com/us VALVES Symbol Port size Orifice (mm) Operating pressure (bar) Material Seat seal Flow (l/min) Solenoid- group *2 Valve model *1 G1/4 1.5 0 ... 40 NBR 70 13B 9500100* G1/4 2 0 ... 35 NBR 120 13B 9500200* 1/4 NPT 2 0 ... 35 NBR 120 13B 9503200* G1/4 3 0 ... 10 NBR 200 13C 9500300* 1/4 NPT 3 0 ... 10 NBR 200 13C 9503300* G1/4 4 0 ... 12 NBR 350 13D 9500400* 1/4 NPT 4 0 ... 12 NBR 350 13D 9503400* G1/4 6 0 ... 5 NBR 550 16D 9501600* 1/4 NPT 6 0 ... 5 NBR 550 16D 9504600* G1/2 12 0 ... 1 NBR 1700 16D 9501700* Symbol Port size Orifice (mm) Operating pressure (bar) Material Seat seal Flow (l/min) Solenoid- group *2 Valve model *1 G1/4 2 0 ... 20 NBR 100 13B 9502210* G1/4 3 0 ... 10 NBR 160 13B 9502310* Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operating pressure: 0 ... 1 bar (0 ... 14 psi) 0 ... 5 bar (0 ... 72 psi) 0 ... 10 bar (0 ... 145 psi) 0 ... 12 bar (0 ... 174 psi) 0 ... 20 bar (0 ... 290 psi) 0 ... 35 bar (0 ... 507 psi) 0 ... 40 bar (0 ... 580 psi) Fluid/ Ambient temperature: -25 ... +80°C (-13...+176°F) NBR Depending on solenoid system and Seal. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Housing:: Brass 2.0401 (Ms 58)Seals: NBR Inner parts: Steel 1.4104 (430 F), Brass 2.0401 (Ms 58) Technical features Approval depends on magnetic system For a.c. solenoid systems with integrated rectifier (40 … 60 Hz) Switching function: Normally closed Technical data Switching function: Normally open *1 Order example: To order a Series 95000 valve, with a 24Vdc coil, Model Number: 9502210024602400. Valve model code 9502210 + Coil code 024602400 = Model Number: 9502210024602400 . To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 9502210000000000. *2 Technical data and ordering information see following pages. *1 Order example: To order a Series 95000 valve, with a 24Vdc coil, Model Number: 9500100024602400. Valve model code 9500100 + Coil code 024602400 = Model Number: 9500100024602400 . To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 9500100000000000. The solenoid valves are used in ATEX- zones, resulting from Protection Class Atex-category of solenoids (see table of solenoids). 95000 2/2-poppet valves electromagnetic actuated, directly controlled G 1/4, 1/4 NPT, G 1/2