Issue link: https://onenorgren.uberflip.com/i/552086
1 21 3 2 1 3 2 1 3 2 1 3 V-32C-EM-F V-32C-EMH-F V-32C-EMR-F 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-F V-52-EMH-F V-52-EMH-F 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR 4 2 5 1 3 4 2 5 1 3 V-53A-EMH 4 2 5 1 3 V-53A-EM V-53A-EMR 3 2 1 3 2 1 3 2 1 3 V-32C-EM-F V-32C-EMH-F V-32C-EMR-F 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-F V-52-EMH-F V-52-EMH-F 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR For further information www.norgren.com/us VALVES Symbol Port size Function Actuation/Return Operating pressure (bar) Flow (l/min) Test certificate IEC 61508 *2 Valve model code *1 G 1/4 3/2 Solenoid/Spring 2.5 ... 8 1300 x 9713535* 1/4 NPT 3/2 Solenoid/Spring 2.5 ... 8 1300 x 9713545* G 1/2 3/2 Solenoid/Spring 2.5 ... 8 2600 9713555* 1/2 NPT 3/2 Solenoid/Spring 2.5 ... 8 2600 9713565* G 1/4 5/2 Solenoid/Spring 2.5 ... 8 1300 x 9710535* 1/4 NPT 5/2 Solenoid/Spring 2.5 ... 8 1300 x 9710545* G 1/2 5/2 Solenoid/Spring 2.5 ... 8 2600 9710555* 1/2 NPT 5/2 Solenoid/Spring 2.5 ... 8 2600 9710565* G 1/4 5/2 Solenoid/Solenoid 2.5 ... 8 1300 9711535* 1/4 NPT 5/2 Solenoid/Solenoid 2.5 ... 8 1300 9711545* G 1/4 5/3 Solenoid/Solenoid, APB 2.5 ... 8 950 9712535* 1/4 NPT 5/3 Solenoid/Solenoid, APB 2.5 ... 8 950 9712545* Symbol Port size Function Actuation/Return Operating pressure (bar) Flow (l/min) Test certificate IEC 61508 *2 Valve model *1 G 1/4 3/2 Solenoid/Spring 2.5 ... 8 1300 x 9713735* 1/4 NPT 3/2 Solenoid/Spring 2.5 ... 8 1300 x 9713745* G 1/2 3/2 Solenoid/Spring 2.5 ... 8 2600 9713755* 1/2 NPT 3/2 Solenoid/Spring 2.5 ... 8 2600 9713765* G 1/4 5/2 Solenoid/Spring 2.5 ... 8 1300 x 9710735* 1/4 NPT 5/2 Solenoid/Spring 2.5 ... 8 1300 x 9710745* G 1/2 5/2 Solenoid/Spring 2.5 ... 8 2600 9710755* 1/2 NPT 5/2 Solenoid/Spring 2.5 ... 8 2600 9710765* G 1/4 5/2 Solenoid/Solenoid 2.5 ... 8 1300 9711735* 1/4 NPT 5/2 Solenoid/Solenoid 2.5 ... 8 1300 9711745* Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operating pressure: 2,5 ... 8 bar (36 ... 116 psi) with internal air supply 0 ... 8 bar (0 ... 116 psi) with external air supply Fluid/Ambient temperature: -40 ... +65°C (SNBR)(-40...+149°F) -25 ... +80°C (HNBR)(-13...+176°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). For outdoor installations all connections must be protected against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Body: Aluminum 3.0615 with surface treatment for rough environmantal conditions. ( Stainless steel DIN 50018: Condensate test with alternating temperatures in sulphuric atmosphere, DIN 50021/ASTM B117-73: Salt spray test with different sodium chloride solutions, tested in ammonia atmosphere). Stainless steel 1.4404 (316 L) Seals: SNBR (special NBR) or HNBR Approval depends on magnetic system Technical data Housing: Aluminum anodized: SNBR -40...+65C *3 Housing: Stainless steel: SNBR -40...+65C *3 Technical features DIN EN 61508 IEC 61508 Add-on manual override The solenoid valves are used in ATEX- zones, resulting from Protection Class Atex-category of solenoids (see table of solenoids). 97105 Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT *1 Order example: To order a Series 97105 valve, with a 24Vdc coil, Model Number: 9713535076302400. Valve model code 9713535 + Coil code 076302400 = Model Number: 9713535076302400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 9713535000000000. Valve function: APB = All Ports Blocked *1 Order example: To order a Series 97105 valve, with a 24Vdc coil, Model Number: 9713735076302400. Valve model code 9713735 + Coil code 076302400 = Model Number: 9713735076302400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 9713735000000000. *2 Since May 2008, Date code A8192 *3 For operation in plants according to IEC 61511/61508 -40 ... +40°C see test certificate (on request)