3
77
P
PRESSURE
SWITCHES
&
SENSORS
For further information www.norgren.com/us
Accessories
*1) Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds
to the maximum testing pressure.
*2) Standard models.
*3) Other NPT versions may be available upon request. Please contact technical support.
Output signal 1 x PNP/1 x analogue 4 ... 20 mA
* Cable with screening
Pressure port
reducing nipple
Surge damper Connector M 12 x 1
90°
Connector M 12 x 1
straight
0574767000000000 (brass) 0574773000000000 (brass) 0523058000000000 (2 m cable, 4-core) 0523056000000000 (90° without
cable)
0523057000000000 (2 m
cable, 4-core)
0523055000000000 (without cable)
0550083000000000 (Stainless
steel)
0553258000000000 (Stainless
steel)
0523053000000000 (5 m cable, 4-core) 0523052000000000 (5 m
cable, 4-core)
0250081000000000 (5 m cable length,
5-core, on PE-requirement*)
Symbol Model Switching pressure
range (bar)
Over pressure*1)
(bar)
Fluid
connection*3)
Output
signal
Display step size
(bar)
0863142000000000*2) 0 ... 10 40 G1/4 1 x PNP / 4 ... 20 mA 0.050
0863342000000000 0 ... 40 100 G1/4 1 x PNP / 4 ... 20 mA 0.200
0863442000000000*2) 0 ... 100 200 G1/4 1 x PNP / 4 ... 20 mA 0.500
0863542000000000 0 ... 160 300 G1/4 1 x PNP / 4 ... 20 mA 0.500
0863642000000000*2) 0 ... 250 500 G1/4 1 x PNP / 4 ... 20 mA 1.000
0863742000000000 0 ... 400 750 G1/4 1 x PNP / 4 ... 20 mA 2.000
0863842000000000 0 ... 630 1000 G1/4 1 x PNP / 4 ... 20 mA 2.000
33D Hydraulic / Allfluid
Electronic pressure switch
0 ... 630 bar G1/4 or Flange