1
49
FM
APPROVED
3
2
1
3
2
1
3
2
1
3
V-32C-E-F
V-32C-EH-F
V-32C-ER-F
2 4
1 5
3
2 4
1 5
3
2 4
1 5
3
V-52-E-F
V-52-EH-F
V-52-EH-F
For further information www.norgren.com/us
VALVES
Symbol Model Port
size
Function Operating
pressure
(bar)
Manual
override/
reset
ATEX
certification
Power
consumption
at 24 Vdc (W)
Ambient
temperature
Y013AA1H1BS 1/4 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 3 T6 (-55 … +50°C),
T4 (+90°C max)
Y013AA3H1BS 1/2 NPT 3/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7.8 T6 (-55 … +50°C),
T4 (+90°C max)
Y015AA1H1BS 1/4 NPT 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7.8 T6 (-55 … +50°C),
T4 (+90°C max)
Y015AA3H1BS 1/2 NPT 5/2 UNI 0 ... 12 Without Ex II 2 GD, Exd IIC 7.8 T6 (-55 … +50°C),
T4 (+90°C max)
Technical data – standard models with conduit connection M20 x 1,5
Reliable and long life,
ideal for a one time
installation
Medium:
Hydraulic and pneumatic –
customer to specify and
confirm compatibility
Operating pressure:
0 ... 12 bar (0 ... 174 psi)
Fluid temperature:
-55 ... +90°C (-67 ... +194°F)
Ambient temperature:
See table.
Air supply must be dry enough to avoid ice formation
at temperatures below +2°C (+35°F)
Materials:
Valve body, trim, coil housing
and top cover:
stainless steel 1.4404 (316 L)
O-rings seats & seals: NBR
Other seal materials available on
request
Technical features
ICO3S
3/2 or 5/2 poppet valves
Electromagnetically actuated, direct solenoid operated. 1/4 NPT ... 1/2 NPT