Norgren Collateral

z7411CT - Distributor Process catalog

Issue link: https://onenorgren.uberflip.com/i/552086

Contents of this Issue

Navigation

Page 31 of 100

1 31 2 1 3 2 1 3 2 2 1 12 3 3 2 2 1 1 12 3 3 2 2 1 12 3 3 2 2 1 1 12 3 3 For further information www.norgren.com/us VALVES Symbol Solenoid- group Port size Operating pressure* (bar) Materials: Seat-seal Manual override- Solenoid operators Test certificate IEC 61 508 *2 97/23EG *7 Valve model *1 A + B G 1/4 0 ... 10 NBR without X — 2401103* A + B G 1/4 0 ... 10 NBR without X X 2401149* A + B 1/4 NPT 0 ... 10 NBR without X X 2401138* Symbol Solenoid- group Port size Operating pressure* (bar) Materials: Seat-seal Manual override- Solenoid operators Test certificate IEC 61 508 *2 97/23EG *7 Valve model *1 A G 1/4 0 ... 10 FPM without — — 2401127* A 1/4 NPT 0 ... 10 FPM without — — 2401147* Symbol Solenoid- group Port size Operating pressure* (bar) Materials: Seat-seal Manual override-Solenoid operators *6 Variants Weight (kg) Test certificate IEC 61 508 *2 97/23EG *7 Valve model *1 A + B G 1/4 0 ... 10 NBR without — 0,55 X X 2401191* A + B 1/4 NPT 0 ... 10 NBR without — 0,55 X X 1025254* A + B G 1/4 0 ... 10 NBR without P in Flange interface *4 0,55 X X 2401109* Symbol Solenoid- group Port size Operating pressure* (bar) Materials: Seat-seal Manual override-Solenoid operators *6 Variants Weight (kg) Test certificate IEC 61 508 *2 97/23EG *7 Valve model *1 A + B G 1/4 0 ... 10 NBR without — 1.00 X — 2401196* A + B G 1/4 0 ... 10 NBR without P in Flange- interface *4 1.00 X X 1025212* A + B 1/4 NPT 0 ... 10 NBR without P in Flange- interface *4 1.00 X X 1025328* DIN EN 61508 IIEC 61508 Approval depends on magnetic system Technical data Housing: Brass with Thread Housing: Stainless steel (1.4404) for aggressive environment Housing: aluminum hard anodized, flanged with NAMUR Interface Medium: Compressed, air filtered, non-lubricated and dry. Other gases and liquid fluids on request Operating pressure: 0 ... 10 bar (0 ... 145 psi) Flow: 340l/min Fluid/Ambient temperature: Fluid: -25°C ... +80°C (-13 ...+176°F) (NBR) -10°C ... +120°C (+14 ...-248°F) (FPM) Water: ... +95°C (+ 203°F) -40°C ... +60°C (-40 ... +140°F) (VMQ) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: stainless steel 1.4404 (316L), brass 2.0402 (Ms 58), hard anodized aluminum 3.0615 Seal: FPM, NBR, VMQ (silicon) Inner parts: stainless steel, brass Technical features Housing: stainless steel (1.4404) for aggressive environment, flanged with NAMUR Interface See solenoid Group A on page 32 See Solenoid Group B on page 33 * Viscosity for gaseous or liquid fluids up to 40 mm2/s. *1 Order example: To order a Series 24011 valve, with a 24Vdc coil, Model Number: 2401196080002400. Valve model code 2401196 + Coil code 080002400 = Model Number: 2401196080002400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 2401196000000000. * Viscosity for gaseous or liquid fluids up to 40 mm2/s. 0695241 *4 Acc. to VDI/VDE 3845 port P in flange for attachment of positioners or to interlinking plate (see data sheet N/en 5.8.300) *6 Add-on manual override, see accessories *7 EG Type examination according to directive 97/23/EC • Particulary for valves with TUV approval and attachment in plants based on safety standards IEC 61511, taking into account to the operating and maintance instructions document 7503444 • The responsibility for the maintance and repair of the solenoid valves lies with the users or the supervisory authority for these process systems. Suited for outdoor use under critical environment conditions The solenoid valves are used in ATEX- zones, resulting from Protection Class Atex-category of solenoids (see table of solenoids). 24011 NAMUR & Inline 3/2 poppet valves electromagnetic actuated, directly controlled G 1/4, 1/4 NPT, flanged with NAMUR interface See solenoid Group A on page 32 See Solenoid Group B on page 33 *1 Order example: To order a Series 24011 valve, with a 24Vdc coil, Model Number: 2401103080002400. Valve model code 2401103 + Coil code 080002400 = Model Number: 2401103080002400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 2401103000000000. See solenoid Group A on page 32 See Solenoid Group B on page 33 *1 Order example: To order a Series 24011 valve, with a 24Vdc coil, Model Number: 2401127080002400. Valve model code 2401127 + Coil code 080002400 = Model Number: 2401127080002400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 2401127000000000. See solenoid Group A on page 32 See Solenoid Group B on page 33 *1 Order example: To order a Series 24011 valve, with a 24Vdc coil, Model Number: 2401191080002400. Valve model code 2401191 + Coil code 080002400 = Model Number: 2401191080002400. To order the valve only, replace the * after the Valve model code from the table above with nine zero's, i.e. 2401191000000000.

Articles in this issue

Links on this page

Archives of this issue

view archives of Norgren Collateral - z7411CT - Distributor Process catalog