Lockable ball valves Simple isolation of specific sections of a compressed air ring main can assist in safety and benefit energy efficiency. Machines left unattended with the supply connected could potentially offer a hazard if unauthorised use occurs. In addition, any air leakage overnight or during shutdown periods increases energy cost. The IMI Norgren lockable ball valve presents a simple, fast solution to the problem. Lockable in the "off" position by means of a simple padlock with downstream air exhausted via a threaded port. Two hand start unit The standard IMI Norgren two hand start unit can be fitted to any machine function where the requirement exists for the operator to utilise both hands in order to begin operation. Both buttons need to be operated within 0.5 seconds in order to achieve an output. The unit is supplied as a strong, sealed unit designed to prevent accidental operation. > Meets requirements of EN574 class IIIB > No additional setting or adjustment required Model Description Port Size Max. Pressure 601812128 Full Bore Lockable Ball Valve G1/2 14 bar 601812138 Full Bore Lockable Ball Valve G1/2 14 bar 601812148 Full Bore Lockable Ball Valve G1/2 14 bar 601812168 Full Bore Lockable Ball Valve G3/4 14 bar 601812188 Full Bore Lockable Ball Valve G1 14 bar Model Description Port Size Max. Pressure M/2720 Two-hand Start Unit G1/8 3 … 8 bar EN 574 CLASS IIIB Lockable "Off" SAFE SYSTEMS 07