Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2015 Norgren, Inc. Simplified Valve Circuit Guide 17 Positive Cylinder Positioning-four Positions. (Poppet Valves Shown) The two solenoid valves are controlled in four different combinations by a double wafer electrical switch to give four distinct positions. Continuously Cycling Cylinder, Time Based. (Poppet Valves Shown) The use of Norgren -05 time delay with a normally open 3-way or 4-way poppet valve per the following diagrams will produce a continuously cycling cylinder, adjustable up to one minute in each direction. Cycle frequency and dwell time can be adjusted individually. Shut-off valves are used upstream of either valve to control start and stop function. CYLINDER IN EX OUT TIME DELAY NORGREN N.O. 3-WAY POPPET VALVE -05 IN EX CYL. 1 CYL. 2 SOLENOID VALVE NO.1 IN EX CYL. 1 CYL. 2 SOLENOID VALVE NO.1 1 2 3 4 1 2 3 4 1 2 3 4 SWITCH CONTROL SOLENOID A SOLENOID B CYLINDER IN EX CYL. 1 CYL. 2 TIME DELAY NORGREN 4-WAY POPPET VALVE -05