Norgren Collateral

z7420BR - Valve Circuit Guide

Issue link: https://onenorgren.uberflip.com/i/508614

Contents of this Issue

Navigation

Page 5 of 26

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2015 Norgren, Inc. Simplified Valve Circuit Guide 4 Three-way valve applied to a cooling air supply Three-way valves can be used as a remote air pilot for larger valves. Panel mounted 3-way control valve Power Valve 2 OUT 3 EX 1 IN 2 OUT 3 EX COOLING AIR 1 IN N.O. 3-way Actuated (Cooling air held off) Note: A normally open 2-way poppet valve can also be used in place of the normally open 3-way above. N.O. 3-way unactuated (Upon loss of pilot signal, valve supplies cooling air .) 1 IN 2 OUT 3 EX IN EX CYL. 1 CYL. 2 Four-way Valves Four-way valves use two 3-way valve functions operated at the same time, one normally closed and one normally open. These valves have two outlet ports that alternate between being pressurized and exhausted. Four-way valves are used to operate double acting air cylinders, control bi-directional air motors and in air circuitry. Also two single acting cylinders can be operated with one 4-way valve. Poppet Valves, 4-way, 4-port The flow paths for an unactuated valve are inlet to cylinder 2 and cylinder 1 to exhaust. When actuated, the inlet is connected to cylinder 1 and cylinder 2 is connected to exhaust. Four-way poppet valves have one exhaust port which is shared by all cylinder ports. EX CYL. 1 CYL. 2 IN