1 51 For further information www.imi-precision.com VALVES Symbol Model Orifice (mm) Port size Kv-value (m 3 /h) Operating pressure (bar) P A 8240000.9101.02400 8 G1/4 1.9 0.1…16 8240100.9101.02400 10 G3/8 3 0.1…16 8240200.9101.02400 12 G1/2 3.8 0.1…16 8240300.9101.02400 20 G3/4 6 0.1…16 8240400.9101.02400 25 G1 9.5 0.1…16 8240500.9101.02400 32 G1 1/4 23 0.1…10 8240500.9151.02400 32 G1 1/4 23 0.1…16 8240600.9101.02400 40 G1 1/2 25 0.1…10 8240600.9151.02400 40 G1 1/2 25 0.1…16 8240700.9101.02400 50 G2 41 0.1…10 8240700.9151.02400 50 G2 41 0.1…16 Symbol Model Orifice (mm) Port size Kv-value (m 3 /h) Operating pressure (bar) P A 8273000.9101.02400 8 G1/4 1.9 0.1…16 8273200.9101.02400 12 G1/2 3.8 0.1…16 8273300.9101.02400 20 G3/4 6 0.1…16 8273400.9101.02400 25 G1 9.5 0.1…16 Brass – For neutral, gases and liquids Models Stainless steel – For aggressive gases and liquids Medium: Neutral gases and liquids (82400) Slightly aggressive gases and liquids (82730) Flow direction: Fixed Operating pressure: 0,1 … 16 bar (1,4 ... 232 psi) for Details, See table Temperature: Fluid –10°C … +90°C (14 ... +194°F) max. Ambient –10°C … +50°C (14 ... +122°F) max. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F) Materials: Body: Brass (82400) or Stainless steel (82730) Seat Seal: NBR Internal parts: Stainless steel, PVDF, For contaminated fluids installations of an upstream filter is recommended. Technical features Solenoid interchangeable without tools (Click-on ® ) Other functions and operating voltages available on request Solenoid operators Design DIN VDE 0580 Voltage range ±10% Duty cycle 100% ED Protection EN 60529 IP65 Connector Form A to DIN EN 175301-803 (included) Electrical details for all solenoid systems Voltage and Frequency Solenoid 9101 *1) Code Voltage Code Frequency Voltage Frequency Power consumption Inrush- Holding- power power 024 00 24 V DC - 8 W 8 W 024 50 24 V AC 50 Hz 15 VA 12 VA 110 50 110 V AC 50 Hz 15 VA 12 VA 120 60 120 V AC 60 Hz 15 VA 12 VA 230 50 230 V AC 50 Hz 15 VA 12 VA Voltage and Frequency Solenoid 9151 *1) 024 00 24 V DC - 18 W 18 W 024 50 24 V AC 50 Hz 45 VA 35 VA 110 50 110 V AC 50 Hz 45 VA 35 VA 120 60 120 V AC 60 Hz 45 VA 35 VA 230 50 230 V AC 50 Hz 45 VA 35 VA ATEX Category Protection Solenoid Standard voltage II2GD EEx m II T4 T 130°C with 3 m Connection cable 9136 24 V DC, 110 V AC, 230 V AC Additional solenoid systems *1) Voltage Buschjost 82400 and 82730 Indirect solenoid actuated diaphragm valves 2/2 N/C, G1/4….G2 According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%. Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog