Norgren Collateral

z7910CT - Express Process catalog

Issue link: https://onenorgren.uberflip.com/i/504900

Contents of this Issue

Navigation

Page 47 of 104

1 47 For further information www.imi-precision.com VALVES Cable gland Protection Ex e, Ex d (ATEX) Model Thread Cable Ø Material Protection class (ATEX) 0588819 M 20x1,5 5,0...8,0 mm Nickel plated brass II2GD Ex e 0588851 M 20x1,5 10...14 mm Nickel plated brass II2GD Ex d 0588925 1/2-14-NPT 7,5...11,9 mm Nickel plated brass II2GD Ex d Connector 0570275 Model Power consumption 24 V DC 230 V AC (W) (VA) Rated current 24 V DC 230 V AC (m A) (m A) Ex-Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/Medium (°C) Electrical connection 0800 16.9 — 703 — — IP 65 (with Connector) -25 ... +60 Fluid: max. +80 Connector DIN EN 175301-803 Form A *6) 3803 — 19.5 — 75 — IP 65 (with Connector) -25 ... +60 Fluid: max. +80 Connector DIN EN 175301-803 Form A *6) 4280 11.4 — 475 — II2G II2D Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T5 -40 ... +50 M20 x 1.5 *6) 4281 — 15.2 — 66 II2G II2D Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T5 -40 ... +50 M20 x 1.5 *6) 4680 11.4 — 475 — II2G II2D Ex d mb IIC T4/T5 Gb Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T5 -40 ... +50 1/2 x 14 NPT *6) 4681 — 15.2 — 66 II2G II2D Ex d mb IIC T4/T5 Gb Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T5 -40 ... +50 1/2 x 14 NPT *6) 4682 11.4 — 475 — II2G II2D Ex d mb IIC T4/T5 Gb Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T5 -40 ... +50 M20 x 1.5 *6) 4683 — 15.2 — 66 II2G II2D Ex d mb IIC T4/T5 Gb Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T5 -40 ... +50 M20 x 1.5 *6) Accessories Solenoids group 16D, Standard Voltage Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED * 6) Connectors/Cable gland is not included, see accessories Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Model Approvals ATEX IECEx 42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X Approvals 95000/96000 Solenoid operators and accessories

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog