Norgren Collateral

z7910CT - Express Process catalog

Issue link: https://onenorgren.uberflip.com/i/504900

Contents of this Issue

Navigation

Page 45 of 104

1 45 For further information www.imi-precision.com VALVES Model Power consumption 24 V DC 230 V AC (W) (VA) Rated current 24 V DC 230 V AC (m A) (m A) Ex-Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/Medium (°C) Electrical connection 0200 12.1 — 504 — — IP 65 (with Connector) -25 ... +60 Fluid: max. +80 Connector DIN EN 175301-803, Form A *6) 3204 — 11.3 — 49 — IP 65 (with Connector) -25 ... +60 Fluid: max. +80 Connector DIN EN 175301-803, Form A *6) 4220 8.9 — 369 — II2G II2D Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +65 T4 -40 ... +55 T5 -40 ... +65 M20 x 1.5 *6) 4221 — 10.0 — 43 II2G II2D Ex e mb IIC T4/T5 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +65 T4 -40 ... +55 T5 -40 ... +65 M20 x 1.5 *6) 4620 8.9 — 369 — II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +70 T4 -40 ... +40 T6 -40 ... +70 1/2-14 NPT *6) 4621 — 10.0 — 43 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +70 T4 -40 ... +40 T6 -40 ... +70 1/2-14 NPT *6) 4622 8.9 — 369 — II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +70 T4 -40 ... +40 T6 -40 ... +70 M20 x 1.5 *6) 4623 — 10.0 — 43 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +70 T4 -40 ... +40 T6 -40 ... +70 M20 x 1.5 *6) Solenoids group 13C, Standard voltages Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED * 6) Connectors/Cable gland is not included, see accessories Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Model Approvals ATEX IECEx FM 42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — Approvals 95000/96000 Solenoid operators and accessories

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog