Issue link: https://onenorgren.uberflip.com/i/504900
1 33 For further information www.imi-precision.com VALVES Model Power consumption 24 V DC 230 V AC (W) (VA) Rated current 24 V DC 230 V AC (m A) (m A) Ex-Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/ Medium (°C) Electrical connection 0827 6.8 — 284 — — IP65 (with Connector) -25...+60 Connector DIN EN 175301-803 Form A *6) 3805 — 10.6 — 46 — IP65 (with Connector) -25...+60 Connector DIN EN 175301-803 Form A *6) 4260 3.9 — 162 — II2G II2D Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP66 (with Connector) -40...+80 T4 -40...+55 T6 -40...+80 M20 x 1.5 *6) 4261 — 5.3 — 23 II2G II2D Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP66 (with Connector) -40...+80 T4 -40...+55 T6 -40...+80 M20x1.5 *6) 4660 3.9 — 162 — II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP66 (with Connector) -40...+80 T4 -40...+55 T6 -40...+80 1/2 NPT *6) 4661 — 5.3 — 23 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP66 (with Connector) -40...+80 T4 -40...+55 T6 -40...+80 1/2 NPT *6) 4662 3.9 — 162 — II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP66 (with Connector) -40...+80 T4 -40...+55 T6 -40...+80 M20x1.5 *6) 4663 — 5.3 — 23 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP66 (with Connector) -40...+80 T4 -40...+55 T6 -40...+80 M20x1.5 *6) 3824 8.9 — 369 v — XP/DIP, Div. 1 & 2 CI. I, Gr. A-D CI. II / III, Gr. E-G T3 (160°C) NEMA 4, 4X, 6, 6P, 7, 9 -20 ... +60 Flying leads 450 mm 3825 — 9.5 — 41 — XP/DIP, Div. 1 & 2 CI. I, Gr. A-D CI. II / III, Gr. E-G T3 (160°C) NEMA 4, 4X, 6, 6P, 7, 9 -20 ... +60 Flying leads 450 mm Solenoid operator, solenoids group B Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *6) Connector cable gland not supplied, see table »Accessories« Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Model Approvals ATEX IECEx FM 382x — — CSA-LR 57643-6 42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X — 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X — Approvals 24011 NAMUR & Inline 3/2 poppet valves Solenoid operators