Norgren Collateral

z7910CT - Express Process catalog

Issue link: https://onenorgren.uberflip.com/i/504900

Contents of this Issue

Navigation

Page 28 of 104

28 1 For further information www.imi-precision.com VALVES Connector, Form A Silencer *1) (plastic) Silencer (stainless steel) *1) Exhaust guard *2) 0570275 M/S2 (G1/4) 0014613 (G 1/4) 0613422 (1/4") M/S4 (G1/2) 0613423 (1/2") Cable gland Ex-Protection. Ex d (ATEX). Nickel. plated brass Model Thread Cable Ø Material Protection class (ATEX) 0588819 M 20x1.5 5.0...8.0 mm Nickel plated brass II2GD Ex e 0588851 M 20x1.5 10...14 mm Nickel plated brass II2GD Ex d 0588925 1/2-14-NPT 7.5...11.9 mm Nickel plated brass II2GD Ex d Accessories *1) For indoors use only Model Approvals ATEX IECEx FM 42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X Approvals 26360 & 80207 Inline/NAMUR Solenoid operators and accessories Model Power consumption 24 V DC 230 V AC (W) (VA) Rated current 24 V DC 230 V AC (m A) (m A) Ex-Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/ Medium (°C) Electrical connection 0242 2.7 - 113 - - IP 65 (with Connector) -25 ... +60 Fluid: max. 80 Connector DIN EN 175301-803 Form A *6) 0245 - 4.2 - - - IP 65 (with Connector) -25 ... +60 Fluid: max. 80 Connector DIN EN 175301-803 Form A *6) 4210 3.9 - 162 - II2G II2D Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5 *6) 4211 - 5.3 - 23 II2G II2D Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5 *6) 4610 3.9 - 162 - II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 1/2-14 NPT *6) 4611 - 5.3 - 23 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 1/2-14 NPT *6) 4612 3.9 - 162 - II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5 *6) 4613 - 5.3 - 23 II2G II2D Ex d mb IIC T4/T6 Gb Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T4 -40 ... +55 T6 -40 ... +80 M20 x 1.5 *6) Solenoid operators Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *6) Connector cable gland not supplied see table, "Accessories" Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog