3
72
PRESSURE
SWITCHES
&
SENSORS
For further information www.imi-precision.com
18D
Electrical connection M12x1 acc. to IEC 947-5-2 - connector are not included in delivery, max. allowable voltage 30 V.
The pressure switch will lose the Ex approval when using other connectors than those listed in the data sheet.
*1) Setpoints should be ideally in the middle of the switching pressure range.
Reference pressure = atmospheric pressure.
Switching pressure must not exceed the indicated values.
*2) Max. values.
Accessories for use with all 18D series switches
Symbol Model Pressure
range *1)
(bar)
Switching pressure difference
Lower range Upper range
(bar) (bar)
Max. Over
pressure *2)
(bar)
Switching
cycles
(1/min)
Materials
Pressure Sealing
sensor housing
Port
size
0880181 -1 ... 0 0.15 0.18 80 100 Aluminum FPM/BR/NBR G1/4
0880281 0.2 ... 2 0.20 0.35 80 100 Aluminum FPM/BR/NBR G1/4
0880381 0.5 ... 8 0.35 0.85 80 100 Aluminum FPM/BR/NBR G1/4
0880481 1 ... 16 0.40 1.20 80 100 Aluminum FPM/BR/NBR G1/4
0880681 1 ... 30 1 5 80 100 Aluminum FPM/BR/NBR G1/4
0881181 -1 ... 0 0.15 0.18 80 100 Aluminum FPM/BR/NBR Flange
0881281 0.2 ... 2 0.20 0.35 80 100 Aluminum FPM/BR/NBR Flange
0881381 0.5 ... 8 0.35 0.85 80 100 Aluminum FPM/BR/NBR Flange
0881481 1 ... 16 0.40 1.20 80 100 Aluminum FPM/BR/NBR Flange
0881681 1 ... 30 1 5 80 100 Aluminum FPM/BR/NBR Flange
Connector Connector M 12 x 1
90°
Connector M 12 x 1
straight
0570110 0523058 (2 m cable, 4-core) 0523056 (90° without cable) 0523057 (2 m cable, 4-core) 0523055 (without cable)
0523053 (5 m cable, 4-core) 0523052 (5 m cable, 4-core)
18D ATEX
Electro-mechanical pressure switch
-1 ... 30 bar G1/4 & Flanged