38
1
2
10 12
2
10 12
2
10 12
1
1
2
1
1
2
1
2
1
2
1
10 12
10 12
10 12
For further information www.imi-precision.com
VALVES
Symbol Model *1) Solenoids
group
Port size Orifice Operating
pressure
(bar)
Flow
(l/min)
2102250 30.5 A G 1/2 12 0 ... 15 1100
2101850 38.5 A G 1/2 12 0 ... 50 1100
Technical data
Valves in protection class IP65 and Ex em
Medium:
For neutral, gaseous and liquid fluids
Operating pressure:
0 ... 15 bar (0 ... 217 psi)
0 ... 50 bar (0 ... 725 psi)
Fluid temperature:
-25 ... +80°C NBR
Ambient temperature:
-25 ... +80°C (-13 ... +176°F)
-25 ... +60°C (-13 ... +140°F)
Depending on solenoid system.
Air supply must be dry enough to avoid ice formation
at temperatures below +2°C (+35°F).
Materials:
Housing: Brass
Seat seal: NBR
Inner parts: Brass,Stainless steel
1.4104 (430 F)
Technical features
*1) When ordering, please indicate solenoid, voltage and current (frequency). Valve function: APB = All Ports Blocked Approval depends on magnetic system.
Seals in either
flow direction
The solenoid valves are used in ATEX-
zones, resulting from Protection Class
Atex-category of solenoids
(see table of solenoids).
21000
2/2-poppet valves electromagnetic actuated, directly controlled
G 1/2
Approval
depends on
magnetic system