Norgren Collateral

z7910CT - Express Process catalog

Issue link: https://onenorgren.uberflip.com/i/504900

Contents of this Issue

Navigation

Page 23 of 104

1 23 For further information www.imi-precision.com VALVES Solenoid operators Model Power consumption 24 V DC 230 V AC (W) (VA) Rated current 24 V DC 230 V AC (m A) (m A) Ex-Protection Protection Class (ATEX-Category) Nominal resistance (according to EN60529) Temperature Ambient/ Medium (°C) Electrical connection 0763 1.9 2.1 *5) 78 11 - IP00 without Connector IP65 (with Connector) -25 ... +60 DIN EN 175 301-803 Form A *5) *6) 4200 0.8 - 38 - II2G II2D Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 M20 X 1.5 *6) 4201 - 1.3 - 6 II2G II2D Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 M20 X 1.5 *6) 4600 0.8 - 33 - II2G II2D Ex d mb IIC T5/T6 Gb Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 1/2 NPT *6) 4602 0.8 - 33 - II2G II2D Ex d mb IIC T5/T6 Gb Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 M20 X 1.5 *6) 4601 - 1.3 - 6 II2G II2D Ex d mb IIC T5/T6 Gb Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 1/2 NPT *6) 4603 - 1.3 - 6 II2G II2D Ex d mb IIC T5/T6 Gb Ex e mb IIC T5/T6 Gb Ex tb IIIC T130°C Db IP 66 (with cable gland) -40 ... +80 T5 -40 ... +70 T6 -40 ... +80 M20 X 1.5 *6) 4802 0.8 – 33 – II2G Ex mb d IIC T4/T6 Gb Ex mb e II T4/T6 Gb IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T6 M20 X 1.5 *6) 4803 1.3 – 6 II2G Ex mb d IIC T4/T6 Gb Ex mb e II T4/T6 Gb IP 66 (with cable gland) -40 ... +50 T4 -40 ... +40 T6 M20 X 1.5 *6) Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *5) Required connector: model 0570275 for V DC; model 0663303 for V AC, to be ordered Solenoid Voltage 200V DC! *6) Connector cable gland not supplied, see table »Accessories« Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Model Approvals ATEX IECEx 42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X 46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X 48xx PTB 06 ATEX 2054 X IECEx PTB 07.0039X Approvals 97105 Inline/NAMUR Solenoid operators Stainless Steel

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog