Issue link: https://onenorgren.uberflip.com/i/504900
22 1 4 2 3 1 5 V-32spec-EM-F V-32spec-EMH-F V-32spec-EMR-F 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-F V-52-EMH-F V-52-EMH-F V-32spec-EM-EM V-32spec-EMH-EMH V-32spec-EMR-EMR 4 2 3 1 5 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR 4 2 3 1 5 V-32spec-EM-F V-32spec-EMH-F V-32spec-EMR-F 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-F V-52-EMH-F V-52-EMH-F V-32spec-EM-EM V-32spec-EMH-EMH V-32spec-EMR-EMR 4 2 3 1 5 4 2 3 1 5 4 2 3 1 5 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR For further information www.imi-precision.com VALVES Symbol Model *1) Port size 1, 3, (5) 2, 4 Actuation/Return Operating pressure (bar) Flow *4) (l/min) Test certificate IEC 61508 *2) 9710505 G 1/4 Flange Solenoid/Spring 2.5 ... 8 1300 x 9710515 1/4 NPT Flange Solenoid/Spring 2.5 ... 8 1300 x 9710595 G 1/2 Flange Solenoid/Spring 2.5 ... 8 2600 9710596 1/2 NPT Flange Solenoid/Spring 2.5 ... 8 2600 9711505 G 1/4 Flange Solenoid/Solenoid 2.5 ... 8 1300 9711515 1/4 NPT Flange Solenoid/Solenoid 2.5 ... 8 1300 Symbol Model *1) Port size 1, 3, (5) 2, 4 Actuation/Return Operating pressure (bar) Flow *4) (l/min) Test certificate IEC 61508 *2) 9710705 G 1/4 Flange Solenoid/Spring 2.5 ... 8 1300 x 9710715 1/4 NPT Flange Solenoid/Spring 2.5 ... 8 1300 x 9711705 G 1/4 Flange Solenoid/Solenoid 2.5 ... 8 1300 9711715 1/4 NPT Flange Solenoid/Solenoid 2.5 ... 8 1300 Approval depends on magnetic system Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operating pressure: 2,5 ... 8 (36 ... 116 psi) with internal air supply 0 ... 8 bar (0 ... 116 psi) with external air supply (G1/2, 1/2 NPT or low power pilot system only) Fluid/Ambient temperature: Valve: -40 ... +65°C (SNBR) (-40...+149°F) -25 ... +80°C (HNBR) (-13...+176°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). For outdoor installations all connections must be protected against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Body: Aluminum 3.0615 with surface treatment for rough environmantal conditions. Approved according to DIN 50018: Condensate test with alternating temperatures in sulphuric atmosphere, DIN 50021/ASTM B117- 73: Salt spray test with different sodium chloride solutions, tested in ammonia atmosphere). Stainless steel 1.4404 (316 L) Seals: SNBR (special NBR) or HNBR Technical features DIN EN 61508 IEC 61508 Add-on manual override Housing: Aluminum anodized, Pilot flange: SNBR -40...+65C *3) Housing: Stainless steel, Pilot flange: SNBR -40...+65C *3) 1/4 NPT Flange Solenoid/spring Aluminum 2.5… 8 1300 0.45 4 9710219 G 1/4 Flange Solenoid/solenoid Aluminum 2.5… *1) When ordering please indicate solenoid, voltage and current type (frequency). *2) Since May 2008, Date code A8192 *3) For operation in plants according to IEC 61511/61508 -40 ... +40°C see test certificate (on request) *4) Flow characteristics conforms to ISO6358 [6 » 5 bar] Note for *4): Connecting pipe / Fitting: In order to ensure and a pressure collapse avoid the flow, the supply air cross section shouldwith 1/4: ≥ 8 mm; with 1/2: ≥≥ 10 mm. With smaller cross section the inlet (A1) should more largely, however at least equally large line at the port (A2; A1). The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids). 97105 NAMUR 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface