Norgren Collateral

z7910CT - Express Process catalog

Issue link: https://onenorgren.uberflip.com/i/504900

Contents of this Issue

Navigation

Page 20 of 104

20 1 3 2 1 3 3 2 1 3 3 2 1 3 V-32C-EM-S V-32C-EMH-S V-32C-EMH-S 2 4 1 5 3 2 4 1 5 3 2 4 1 5 3 V-52-EM-S V-52-EMH-S V-52-EMH-S 2 4 1 5 3 2 4 1 5 3 1 5 3 2 4 V-52B-EM V-52B-EMH V-52B-EMR 4 2 5 1 3 4 2 5 1 3 V-53A-EMH 4 2 5 1 3 V-53A-EM V-53A-EMR For further information www.imi-precision.com VALVES Connector DIN EN 175301-803 Silencer *1) (plastic) Silencer (stainless steel) *1) Exhaust guard *2) 0570275 Form A M/S2 (G1/4) 0014613 (G 1/4) 0613422 (1/4") 0663303 Form A (with rectifier) C/S2 (1/4NPT) 0613678 (1/4 NPT) 0680003 Form B Model *1) Nominal resistance RN Coil (Ω) Required switching min. Current min (mA) Rated currentIon RW 50 Coil (Ω) Required switching at terminal RW 50 (V) Temperature Ambient/ Medium (°C) 3039 *6) 275 37 345 13,8 T6 -40 ... +50 T4 -40 ... +85 Symbol Model *1) Port size Function Actuation/Return Operating pressure (bar) Flow (l/min) 9713032 G 1/4 3/2 Solenoid/air spring 2 ... 8 750 9713042 1/4 NPT 3/2 Solenoid/air spring 2 ... 8 750 9710032 G 1/4 5/2 Solenoid/air spring 2 ... 8 750 9710042 1/4 NPT 5/2 Solenoid/air spring 2 ... 8 750 9711032 G 1/4 5/2 Solenoid/Solenoid 2 ... 8 750 9711042 1/4 NPT 5/2 Solenoid/Solenoid 2 ... 8 750 9712032 G 1/4 5/3 APB Solenoid/Solenoid, APB 2 ... 8 500 9712042 1/4 NPT 5/3 APB Solenoid/Solenoid, APB 2 ... 8 500 Medium: Filtered, non-lubricated or dry compressed air Operating pressure: 2 ... 8 bar (29 ... 116 psi) Fluid/Ambient temperature: Valve: -15 ... +60°C (-5 ... 140°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Materials: Housing: Aluminum 3.0615 anodized Pilot flange: Plastic (PBT) Seals: NBR Technical features *1) For indoors use only *2) For outdoors use ~ 0,2 (bar) Accessories When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in account. On the other hand, the low effective inductivity and capacity can be ignored. *6) Connector not supplied, required connector: model 0570275 For intrinsically safe circuits, Protection class Ex ia IIC T6/T4 (cat. II 2G) Solenoid operators Standard voltages 24 V d.c., 230 V a.c., other voltages on request. *2) Valves can be operated with DC only. For 230V AC application please use 206V DC coil together with recifier plug 0663303 *6) Connector is not scope of delivery, see table »Accessories« Technical data *1) When ordering, please indicate solenoid, voltage and current (frequency). Valve function: APB = All Ports Blocked Approval depends on magnetic system Manual override with detent standard Model Power consumption Rated current Ex-Protection Protection Class (ATEX- Category) IP-Protection According to EN60529 Temperature Ambient/ Medium (°C) 24 V DC (W) 230 V AC (VA) 24 V DC (mA) 230 V AC (mA) 3050 1.8 - 70 - - IP 65 (Connector DIN EN 175301-803, Form B) *6) -15 ... +50 3034 0.7 2.0 *2) 29 4 - IP 65 (Connector DIN EN 175301-803, Form A) *6) -15 ... +50 3062 2.7 - 115 - II2G II2D Ex mb IIC T5 Gb Ex mb tb T95°C Db IP 65 (with 3 m cable) -20 ... +50 3063 - 2.1 - 9 II2G II2D Ex mb IIC T5 Gb Ex mb tb T95°C Db IP 65 (with 3 m cable) -20 ... +50 Model Approvals ATEX FM 306x PTB 03 ATEX 2015 X — 3039 PTB 03 ATEX 2134 CSA-LR 51090-4 Approvals The solenoid valves are used in ATEX- zones, resulting from Protection Class Atex-category of solenoids(see table of solenoids). 97100 Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Articles in this issue

Archives of this issue

view archives of Norgren Collateral - z7910CT - Express Process catalog