Issue link: https://onenorgren.uberflip.com/i/1528936
263 For further information, visit www.norgren.com and use the new improved search function. If you cannot see the option you require please contact us. 5 FIT TINGS 2 1 2 1 T60 Part Number Port size NPT Drop pressure at shut off flow (psi) Shut off flow rate at 100 psi Flow at 100 psi DP 1 psi (scfm) T60A2890 1⁄4" 2.0 17.6 13.8 T60A2891 1⁄4" 4.4 29.7 13.8 T60A3890 3⁄8" 2.0 41.1 28.6 T60A3891 3⁄8" 4.4 68.2 28.6 T60A4890 1⁄2" 2.0 68.2 49.2 T60A4891 1⁄2" 4.4 102.3 49.2 T60A6890 3⁄4" 2.0 102.3 91.1 T60A6891 3⁄4" 4.4 169.5 91.1 T60A8890 1" 2.0 195.0 144 T60A8891 1" 4.4 271.0 144 T60AB890 1-1⁄2" 2.0 394.0 307 T60AB891 1-1⁄2" 4.4 568.0 307 IN-LINE EXCESS FLOW SHUT-OFF VALVES T60 AIR FUSES, 1/4 TO 1-1/2" NPT Technical Data Medium: Compressed air, filtered, lubricated and non lubricated inert gases Operating pressure: Maximum 232 psi (16 bar) Minimum according to hose length Drop pressure at shut-off flow: 2 to 4.5 psi (0.14 or 0.3 bar) Mounting: In-line two way valve. To be inserted between fixed air supply and flexible hose air line. See guidelines for typical installation. Materials: Body: aluminum Internal parts: brass Spring: stainless steel Operating temperature: 0°** to 175° F (-20° to 80°C) **Consult our Technical Service for use below 35°F (2˚C). At low temperature ensure air fuse is not subjected to freezing conditions which may prevent its function. » Assists in complying with safety regulations » Tamper proof » Compact and safe design » Low pressure drop » Automatically resets aer failure correction » High corrosion resistance » High air pressure rating ECM575A.Symbol based on Symbol 24 Section 00 ECM575A.Symbol with annotations based on Symbol 24 Section 00 1 11 2 SHUTTLE VALVES 1/8" to 1/4" NPT Technical Data Fluid: Compressed air, filtered, lubricated and non- lubricated, inert gases Operation: Shuttle valve Mounting: Through holes in valve body Operating Pressure: 10 to 145 psi (0.7 - 10 bar) Materials: Body: Zinc Ball: Nitrile Seat: Brass Operating Temperature: 0° to 175°F (-20°* to +80°C) *Consult our Technical Service for use below 35°F (2˚C) » Allows two independent signal sources to be connected to a common pilot line » Can be used to perform an 'OR' logic function » Selects the highest of two applied pressures » Can be combined to operate from three or more sources » Valves can be ganged together Product Number Port size NPT Flow Factor Cv T65A1800 1/8" 0.42 T65A2800 1/4" 0.64 NPT according to ANSI B1.20.1 Shuttle Valves Online at norgren.com