EXCELON® PLUS MODULAR SYSTEM
HT84T - 3/2 shut-off valve for extreme temperature applications
Technical Data
» Port size: 3/8" ... 3/4" (PTF/ISO G)
» Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products
» 3/2 way function
» Threaded exhaust port
» Lockable in closed position with padlock
» Salt Spray compliant to ISO 9227
Medium:
Compressed air only
Maximum supply pressure:
290 psi (20 bar)
Port size:
G3/8, G1/2, G3/4,
3/8 PTF, 1/2 PTF, 3/4 PTF
Flow:
From IN to OUT ports:
1/2": 162 dm3/s at 6.3 bar and
Δp 0.5 bar pressure drop, 1.8 dm3/s
from OUT to exhaust port.
Operating pressure:
91 psi (6.3 bar)
Ambient/Media temperature:
-40 ... +80°C (-40 ... +176°F)
Air supply must be dry enough
to avoid ice formation at
temperatures below +2°C (+35°F).
Atex:
Filters HT84 are in conformity
with Atex 2014/34/EU
II 2 GD
Ex h IIC T6 Gb
EX h IIIC T85°C Db
Materials:
Body: Die cast aluminum
Body covers: ABS (Magnum 3904)
Elastomers: NBR
Technical data HT84T - andard models
Symbol
Port
size
Function Valve type Exhaust port forms Weight
lb (kg)
Model
2
1
3
3/8 3/2 Ball valve Exhaust port threaded 1/4 1.1 (0.48) HT84T-3AA-B1N
1/2 3/2 Ball valve Exhaust port threaded 1/4 1.1 (0.48) HT84T-4AA-B1N
3/4 3/2 Ball valve Exhaust port threaded 1/4 1.1 (0.48) HT84T-6AA-B1N
HT84T-HHA-B1N
Option selector
Function Substitute
3/2 T
Thread form Substitute
PTF A
ISO G parallel
(standard)
G
Port size Substitute
3/8" 3
1/2" 4
3/4" 6
+80°C