96
For further information, visit www.norgren.com
and use the new improved search function. If you cannot see the option you require please contact us.
2
VALVES
4/2 Solenoid/spring (110/120 VAC)
Model Basic size Port size Flow Operating Pilot pressure
2
Operator Repair kit
inch PTF Cv pressure (psi) (psi)
F1024C-CC 1/2 1/2 4.0 to 5.5 30 - 150 30 - 150 -CC 53474-06
F1025C-CC 1/2 3/4 4.8 to 5.8 30 - 150 30 - 150 -CC 53474-06
F1036C-CC 1 1 11.3 14.3 30 - 150 30 - 150 -CC 53475-06
3/2 Solenoid/spring (110/120 VAC)
Model Basic size Port size Flow Operating Pilot pressure
2
Operator Repair kit
inch PTF Cv pressure (psi) (psi)
D1023C-CY
1
1/2 3/8 1.7 to 1.8 30 - 150 30 - 150 -CY 53474-03
D1024C-CY
1
1/2 1/2 4.6 to 5.8 30 - 150 30 - 150 -CY 53474-03
D1025C-CC
1
1/2 3/4 5.4 to 6.2 30 - 150 30 - 150 -CC 53474-03
D1036C-CC
1
1 1 13.2 to 14.6 30 - 150 30 - 150 -CC 53475-01
2/2 Solenoid/spring (110/120 VAC)
Model Basic size Port size Flow Operating Pilot pressure
2
Operator Repair kit
inch PTF Cv pressure (psi) (psi)
A1014C-CY
1
1/2 1/2 5.3 30 - 150 30 - 150 -CY 53474-03
A1015C-CY
1
1/2 3/4 6.5 30 - 150 30 - 150 -CY 53474-03
A1026C-CC
1
1 1 10.7 30 - 150 30 - 150 -CC 53475-01
4/2 Air/spring
Model Basic size Port size Flow Operating Pilot pressure
2
Operator Repair kit
inch PTF Cv pressure (psi) (psi)
F1024H-A1 1/2 1/2 4.0 to 5.5 0 - 300 30 - 300 -A1 53474-06
F1025H-A1 1/2 3/4 4.8 to 5.8 0 - 300 30 - 300 -A1 53474-06
F1036H-A1 1 1 11.3 14.3 0 - 300 30 - 300 -A1 53475-06
1 Normally closed
2 Pilot pressure must be equal to or greater than the operating pressure
-A1
Air
-CC
30 mm coil,
DIN 43650
-CY
22 mm
Industrial Standard
Operators
PROSPECTOR POPPET VALVES
1/2" Basic with 1/2" or 3/4" threaded ports