VALVES
Standard Models
Model
No.
Port Size Outlet
Pressure
Control
Signal
Unit
measure
Electrical Connection Cable Grip
Connector
6 ft molded cable
VP1006PK401A00 1/4" NPT 3-90 psi 4-20mA PSI 30mm DIN 43650, form A 54933-05 54933-06
VP1008PK401A00 1/4" NPT 3-120 psi 4-20mA PSI 30mm DIN 43650, form A 54933-05 54933-06
VP10 Electronic Pressure Regulator
1/4" NPT
» Reliable, rugged proportional
I/P and E/P converters
» Suitable for a wide
range of applications
» Excellent accuracy
» High flow versions
» NEMA4 environmental
protection in normal operation
Technical Data
Medium:
Oil free, dry air, filtered to 5
micron
Flow capacity:
Up to 10 scfm (300 l/min)
Operating pressure:
At least 10 psig (0.7 bar) above
maximum required output pres-
sure, 145 psig (10 bar) maximum
Connections:
NPT 1/4"
Operating temperature:
-4° to 160°F (-20°C to 70°C)
Response time:
<30 psig: less than 0.5 seconds
for 10-90% step change
>30 psig: 2 seconds for 10-90%
step change
Total error:
±0.5% of span (typical, independ-
ent error includes the combined
effect of non-linearity, hysteresis,
deadzone and repeatability)
Supply sensitivity:
>0.025% span output change
per % supply pressure change
Failure mode:
Signal falls to bleed pressure
when electrical supply fails
Material of construction:
Zinc die-casting passivated and
epoxy paint, nitrile diaphragms,
stainless steel/nylon flapper nozzle
and supply valve
Mass: 3.3 lbs (1500g) approx.
Online at