08 AMT Performance, validation & testing » Air dryer service intervals: 30,000 operating hours (10 year service intervals) » Significant weight reduction compared with conventional dryer » Reduced pressure drop across the dryers » Reduced air purge requirement » Total flexibility in mounting orientation – horizontal or vertical » Robust and durable » Dryer performance is not affected by orientation » Dryer performance is not affected by shock and vibration » Operating pressure range: 6 bar (72 psig) to 12 bar (188 psig) » Ambient operating temperature range: -40°C to +80°C (-40°F to 176°F) » Typical dew point suppression: 40°C (104°F) » On-going continuous testing has resulted in better than 40°C (104ºF) suppression Performance Validation & Testing summary table Standard Description Date EN61373 Shock and Vibration Category 1 Class B 2010 MIL-STD-810G Shock and Vibration Category 11, Fig 514.7C 2008 EN45545-2 Fire protection on Railway Vehicles 2013 NFPA 130, 49 CFR §238.105, BSS-7239 Fire and Smoke EN50155 > EN60068-2-1 > EN60068-2-2 > EN60068-2-30 Electronic Equipment used on Rolling Stock Test A Cold Temperature -50°C, 80cc/min external leakage @ 10 bar -20°C, 10cc/min external leakage @ 10 bar Test B Dry Heat +80°C, 10cc/min external leakage @ 10 bar Damp Heat, Cyclic +55°C, @ 95% RH. 10cc/min external leakage @ 10 bar Electromagnetic Compatibility 2007 EN ISO 9227 Salt Spray Test to 1000 hrs 2012 EN 60529 Ingress protection to IP65 2013 N/A Low Temperature Park Test (7 day @ -50°C) N/A Life cycle 30,000 hours of compressor flow