Norgren Collateral

z9619BR Redundant Valve Manifold

Issue link: https://onenorgren.uberflip.com/i/1505201

Contents of this Issue

Navigation

Page 14 of 15

RVM Systems 15 Hydraulic RVM Systems Hydraulic 2oo3 Fail Safe Trip System for Gas and Steam Turbines » Available for low and high operational pressure 5 – 320 bar » Different sizes provide high flow availability 200 – 4000 l/min » Cartridges sizes DN 16; 25; 32; 40; 50 and 63 » Fast reaction time » Safety Control – direct monitoring of solenoid valves position closed open (proximity switches) » SIL 3 approval » IP 65 » Certification to ATEX, GOST » Redundant cartridges » Partial Stroke Testing Option » Maintaining Safety 2oo3 during operation (redundant 2oo3 system) » Prepared outlets for pressure transducers The Herion Hydraulic 2oo3 system provides safety and availability for main shut off emergency process valves with hydraulic actuators. Using three identical solenoid valves to create a flexible 2oo3 voting logic for unequalled failure tolerance, the system uses redundant cartridges which allow high flow rate and a quick response time. Hydraulic 2oo3 system