Main technical features - IO-Link Masters
NC series - IO-Link Maers,
I/O Modules and Accessories
> Indurial Ethernet
connectivity products
> IO-Link Maer provide
a gateway to PROFINET
and EtherNet/IP
> Standard building blocks
make syem design
modular and simple
> Inallation time is
reduced as all cables
are premade, plug and
socket, making it all plug
and play
> IO-Link enabled Valve
Manifolds can be
connected to a maer
port on a single andard
cable
> Electrical design
is simplified as the
I/O Modules can be
configured depending
on the input and output
requirement.
> Diagnoics can pinpoint
faults in the whole
network quickly and
precisely
Operating voltage (V):
20...30 DC; (US; to SELV/PELV)
Current consumption (mA):
300...3900; (US)
Protection class: III
Additional voltage supply (V):
20...30 DC; (UA)
Max. current load total (A):
8
Current rating per port (A):
2; (adjustable: 0...2; Factory
setting: 2)
Total number of inputs and
outputs:
24; (configurable)
Number of digital inputs:
12; (IO-Link Port Class A: 4 x 2)
(IO-Link Port Class B: 4 x 1)
Number of digital outputs:
12
Ethernet transmission standard:
10Base-T; 100Base-TX
Ethernet transmission rate:
10; 100
IO-Link Master transmission
type:
COM 1/COM 2/COM 3
IO-Link revision:
1.1
IO-Link Master number of ports
class A:
4
IO-Link Master number of ports
class B:
4
Ambient temperature:
-13 ... 140°F (-25…60°C)
Storage temperature:
-13 ... 185°F (-25…85°C)
Max. relative air humidity:
90%
Protection:
IP 65; IP 66; IP 67
Materials
Housing: PA
Socket: brass nickel plated