Page 75 of 287

76 M O D U L A R VAC U U M G E N E R ATO R S 1 For more information or for additional configurations, please contact us at NASInsideSales@imi-precision.com SETPOINT 'A' AIR SUPPLY PORT 'B' VACUUM PORT VACUUM GAUGE 3X Ø 'D' MOUNTING HOLES J K N M P R S Ø W SET POINT ADJUSTMENT KNOB F 'C' EXHAUST PORT U V T X VENT SILENCER 'E' (2X) AUXILIARY PORTS CHECK VALVE Dimensions inches (mm) Model Units A B C D E F J K M N P R S T U V W X NVP90M0- 3***-S27A38 Imperial 3/8 NPTF 1/2 NPTF 1/2 NPTF 0.21 1/8 NPTF 0.50 0.74 3.90 0.20 1.30 2.40 3.50 5.00 11.20 1.72 2.30 3.23 7.00 NVPM90M0- 3***-S27A38 (Metric) (G 3/8) (G 1/2) (G 1/2) (5.3) (G 1/8) (12.7) (18.9) (99.0) (5.1) (33.0) (61.0) (88.9) (127.0) (284.5) (43.7) (58.4) (82.0) (177.8) NVP90C Air Saver NVPH90C0-HHHH-S27A38 Option selector Series Substitute NVP (Imperial Thread) NVPM (Metric Thread) M Vacuum Flow Level Substitute Venturi Cartridge 300 300 Venturi Cartridge 350 350 Vacuum Level Substitute 20"Hg @ 80PSI (Standard) M 28"Hg @ 80PSI (Standard) H 20"Hg @ 60PSI Y 28"Hg @ 60PSI Z Accessories Substitute Extra Ports / NVG-150-GF A38 Silencers NFA-51-.500 (72dB) S27