259
ACC
E
S
S
O
R
I
E
S
8
For more information or for additional configurations,
please contact us at NASInsideSales@imi-precision.com
SWITCHES /SENSORS
Wiring Schematic for NVXX Series
NVXXN-QD-6 / NVXXP-QD-6
Setting Pressure Range: -101 ~ 0 kPA (-29.9" ~ 0"Hg )
Withstand Pressure: 300 kPA (43.5 PSI)
Fluid: Air, Non-Corrosive /Non-flammable Gas
Power Supply Voltage: 12 to 24VDC ± 10%, Ripple (P-P) 10% or less
Output Method: NPN Open Collection 30V 80mA / PNP Open Collection 80mA
Hysteresis: 1~10% of Setting Presssure (Adjustable)
Setting Point: 1 Point
Operation Indicating Lamp: Light at ON (Red)
Current Consumption: 1 output: NPN & PNP: 21mA max.
Repeatability (Switch Output): ≤±1% F.S.
Response Time: 5ms or less
Environment
Enclosure IP 40
Amb. temp range Operation: 0~50°C, Storage: -20 ~ 60°C (no condensation or freezing)
Amb. humidity range Operation/Storage: 35 ~ 85% RH (no condensation)
Withstand Voltage 1000VAC in 1-min (between case and lead wire)
Insulation resistance 50Mohm min. (at 500VDC between case and lead wire)
Vibration Total amplitude 1.5mm, 10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y, and Z
Shock 980m/S
2
(100G), 3 times each in direction of X, Y, and Z
Temperature Characteristic: ±3% F.S. (standard: 25ºC)
Port Size: 1/8" NPT, G 1/8, 10-32, M5
Weight: Approx. *1.2 oz (32g) (with male connector)
NVXXN
NPN OUTPUT
NVXXP
PNP OUTPUT
NVXX(N, P)-QD-6 Series Specifications: