206
E
N
D
-
O
F
-A
R
M
TO
O
L
I
N
G
7
For more information or for additional configurations,
please contact us at NASInsideSales@imi-precision.com
NCRVT
Temperature ranges for normal operation of end effector.
Cup Working temperature
C01 14˚ F to 140˚ F (-10˚ C to 60˚ C)
C02 50˚ F to 122˚ F (10˚ C to 50˚ C)
C03 50˚ F to 122˚ F (10˚ C to 50˚ C)
C04 14˚ F to 140˚ F (-10˚ C to 60˚ C)
C05 14˚ F to 140˚ F (-10˚ C to 60˚ C)
Operating Ranges
NOTES:
1 4X factor of safety applied
2 Exceeds load capacity of UR 3
3 Exceeds load capacity of UR 5
4 Exceeds load capacity of UR 10
5 Actual time will vary based on cup selection, leakage and part shape
6 Average performance data shown. All data is for reference only. Please contact factory for assistance with your application
Air consumption
(scfm [slpm])
L M H
10" Hg
(339 mbar)
20" Hg
(677 mbar)
28" Hg
(948 mbar)
060 N/A 0.50 (14.2) 0.80 (22.6)
090 0.50 (14.2) 1.40 (39.6) 1.80 (51.0)
100 1.40 (39.6) 1.80 (51.0) 2.80 (79.3)
150 1.80 (51.0) 2.80 (79.3) 4.80 (135.9)
Maximum recommended load
(lb [kg])1
L M H
10" Hg
(339 mbar)
20" Hg
(677 mbar)
28" Hg
(948 mbar)
C02 3.90 (1.8) 7.90 (3.6)
2
11.00 (5.0)
3
C03 5.50 (2.5)
2
10.90 (4.9)
3
15.30 (6.9)
3
C04 8.50 (3.9)
2
17.10 (7.8)
3
23.90 (10.8)
4
C05 4.80 (2.2)
2
9.50 (4.3)
3
13.30 (6.0)
3
Approximate time to reach
full vacuum (seconds)5
L M H
10" Hg
(339 mbar)
20" Hg
(677 mbar)
28" Hg
(948 mbar)
060 N/A 1.2 4.2
090 0.2 0.6 1.5
100 0.1 0.3 1.3
150 0.1 0.3 0.7
"H" Models "M" Models "L" Models
Performance Data