Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Automation Solutions, LLC 16141UI 10/20 Step 1 Step 4 Step 3 Step 2 Align bushing with drive pin Remove M5 screw Remove side plate Push sensor in direction of arrow M5 X 16mm screw 3. Installation: 3.1. (Step 1) Take off the side plate from the side of the gripper which the sensor is to be mounted to by removing the 5mm screw. (Step 2) Align the brass bushing in sensor to the drive pin in the gripper. (Step 3) Keeping the sensor parallel to the side of the gripper, move the sensor close enough so that the dowel pins align with the slots in the frame. From that point the sensor is pushed farther onto the gripper with a motion indicated in the Step 3 figure. (Step 4) Clean and apply Loctite 262 or equivalent to supplied screw (M5 X 1.0 X 16mm SHCS). Insert screw through sensor and tighten to 72in-lb.