Norgren Collateral

PGS Gripper Part Presence Sensor User Instructions

Issue link: https://onenorgren.uberflip.com/i/1340317

Contents of this Issue

Navigation

Page 2 of 3

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Automation Solutions, LLC 00551UI REV: 001 ECN #26412.03 10/20 4. Wiring: The part present sensor provides a single output which is activated based on the material thickness detected each time the gripper closes. This output will turn on when the gripper is clamped on a sheet having a thickness greater than a threshold determined by the sensor during calibration. This threshold is calculated to provide a reliable indication of part presence while ignoring typical minor variations in sheet thickness. This output will be off when the gripper is open or when the detected thickness is less than this established threshold. Table 1 outlines the various states of the Sensor LED and Part Present Output. Table 1 Gripper state Red LED State Part Present Output Un-calibrated Off Off Gripper Closed (no material) Off Off Clamped on 1 sheet or more On On Gripper Open Off Off Black Brown Blue 10–30 VDC White 100mA Load Max 4 Pin Male Micro Black Brown Blue Wiring for NPN Sensors: 1-Brown 4-Black 2-White 3-Blue 10–30 VDC White 100mA Load Max Wiring for PNP Sensors: 3 Pin Male Pico 3-Blue 4-Black 1-Brown Connector for PNP/NPN 1-V+ 2-No Connect 3-Common 4-Part Present Output Connector for PNP/NPN 1-V+ 2-No Connect 4-Part Present Output NO WHITE WIRE ON PICO NO WHITE WIRE ON PICO

Articles in this issue

Archives of this issue