Page 0 of 3

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2020 Norgren Automation Solutions, LLC 10/20 00551UI REV: 001 ECN #26412.01 PGS Gripper Part Present Sensors User In ruction Part Present Sensor Kit Part Present Sensor Kit Micro Catalog # Pico Catalog # Description SGS40042-K SGS40042P-K NPN SGS40043-K SGS40043P-K PNP SGS40042F-K SGS40042FP-K NPN Flange Jaw SGS40043F-K SGS40043FP-K PNP Flange Jaw Note: Whenever any part of the gripper is replaced including pads the sensor will need to be calibrated again. 1. NPN/PNP Sensor Technical Data: Micro Sensor Connector: 4 - Pin One Key (male) Micro Type Connector Pico Sensor Connector: 3 - Pin (male) Pico Type Connector Supply Voltage Range: 10 - 30 VDC Maximum Continuous load current: 100mA (max) Operating Temperature Range: 0°C to +60°C Response Time: 50ms max Indicator Light: Red Short Circuit Protection: Yes Overload Protection: Current Limits at 325mA Typ. Reverse Polarity Protection: Up to 36 volts DC Interface: 3 - wire device Sensor Housing: Zinc Housing Seal: IP68 2. User Interface: