Life Science

KIP_Valves_S2_9-29

Issue link: https://onenorgren.uberflip.com/i/1299910

Contents of this Issue

Navigation

Page 2 of 3

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2014 - 5769n) © 2020 Norgren en 5.8.301.003 08/20 Orifice Diameter MOPD (psi) Cv Value Body Cv Value Endstop Part Numbering Body Stop 1/32 1/32 250 0.035 0.025 2***70 3/64 3/64 160 0.050 0.065 2***71 1/16 1/16 120 0.085 0.115 2***72 5/64 5/64 80 0.125 0.140 2***73 3/32 5/64 60 0.165 0.140 2***74 1/8 5/64 35 0.240 0.140 2***75 5/32 5/64 20 0.285 0.140 2***76 Series 2 - 3/2 Directional Control Series 2 - 2/2 NC Cv and MOPD Values Orifice Diameter MOPD (psi) Cv Value Part Numbering Cv Value Body Low Watt Specifications (MOPD (psi)) Body Stop 2.0 Watt 2.5 Watt 3.0 Watt 1/32 - 1000 0.035 2***10 0.030 140 225 405 3/64 - 600 0.050 2***11 0.050 105 190 315 1/16 - 400 0.095 2***12 0.085 55 85 155 5/64 - 300 0.135 2***13 0.125 40 60 105 3/32 - 250 0.175 2***14 0.170 25 35 70 1/8 - 150 0.245 2***15 0.225 25 35 50 5/32 - 100 0.290 2***16 0.280 13 20 35 For low watt valves, please use the prefix; B for 2.0 watt; C for 2.5 watt; and D for 3.0 watt as shown Series 2 - 2/2 NO Cv and MOPD Values Orifice Diameter MOPD (psi) Cv Value Part Numbering Body Stop - 1/32 400 0.035 2***20 - 3/64 300 0.050 2***21 - 1/16 180 0.095 2***22 - 5/64 140 0.135 2***23 Series 2 - 3/2 MP Cv and MOPD Values Orifice Diameter MOPD (psi) Cv Value Body Cv Value Endstop Part Numbering Body Stop 1/32 1/32 175 0.035 0.025 2***60 3/64 3/64 125 0.050 0.065 2***61 1/16 1/16 100 0.085 0.115 2***62 5/64 5/64 75 0.125 0.140 2***63 3/32 5/64 50 0.165 0.140 2***64 1/8 5/64 25 0.240 0.140 2***65 5/32 5/64 15 0.285 0.140 2***66 Series 2 - 3/2 NC Cv and MOPD Values Orifice Diameter MOPD (psi) Cv Value Body Cv Value Endstop Part Numbering Body Stop 1/32 1/32 250 0.035 0.025 2***40 3/64 3/64 175 0.050 0.065 2***41 1/16 1/16 125 0.085 0.115 2***42 5/64 5/64 100 0.125 0.140 2***43 3/32 5/64 75 0.165 0.140 2***44 1/8 5/64 45 0.240 0.140 2***45 5/32 5/64 20 0.285 0.140 2***46 Series 2 - 3/2 NO Cv and MOPD Values Orifice Diameter MOPD (psi) Cv Value Body Cv Value Endstop Part Numbering Body End 1/32 1/32 200 0.035 0.025 2***50 3/64 3/64 150 0.050 0.065 2***51 1/16 1/16 125 0.085 0.115 2***52 5/64 5/64 100 0.125 0.140 2***53 3/32 5/64 75 0.165 0.140 2***54 1/8 5/64 60 0.240 0.140 2***55 5/32 5/64 25 0.285 0.140 2***56 For free vent, change fih digit from 4 to 3 Consult Technical Support for low watt options for 3/2 NC valves Consult Technical Support for low watt options for 3/2 MP valves

Articles in this issue

Archives of this issue

view archives of Life Science - KIP_Valves_S2_9-29