HOW TO SPECIFY
Operating Medium: Air
Maximum Operating Pressure: 10.0 bar (140 PSI)
Ambient and Fluid Temperature: -10° C to 70° C (15° F to 160° F)
Lubrication: PTFE impregnated grease
Standard Rod End: Female
Stroke Tolerance:
12-50mm bore: ± .6mm (.025 inch)
63-100mm bore: ± .8mm (.030 inch)
Cylinder Mounting (Standard):
Through hole with counterbores both ends
Front and Rear threaded
Maximum Sideload: Refer to page 58 for specific bore size and stroke length
Expected Service Life: 2500 kilometers (1500 miles)*
Bore Direction
Power Factor
(kg/bar)
Power Factor
(lb/psi)
12mm (1/2")
Extend 1.9 0.30
Retract 0.8 0.10
16mm (5/8")
Extend 3.5 0.55
Retract 1.5 0.20
20mm (3/4")
Extend 5.5 0.86
Retract 2.4 0.40
25mm (1")
Extend 8.4 1.33
Retract 3.8 0.60
32mm (1-1/4")
Extend 13.8 2.19
Retract 6.0 0.90
40mm (1-1/2")
Extend 22.7 3.59
Retract 10.6 1.60
50mm (2")
Extend 35.7 5.65
Retract 16.5 2.60
63mm (2-1/2")
Extend 58.3 9.22
Retract 28.0 4.30
80mm (3-1/4")
Extend 93.6 14.80
Retract 45.4 7.0
100mm (4")
Extend 149.0 23.56
Retract 71.5 11.1
Theoretical Cylindrical Forces
To determine the estimated force generated by the QC cylinder on extend or retract, use the appropriate power factor below and
multiply it to the input working pressure to cylinder. Forces generated by 3C cylinders are found on page 222.
Force (kg or lb) = Power Factor X Pressure (bar or PSI)
3C and QC Cylinder Options and Dimensions
Engineering Specifications
*For filtered, lubricated air, no-load conditions; if unlubricated, life is approximately 1/3.