Datasheets

Mitsubishi Servo Motors Norgren Datasheet

Norgren Featured Datasheets

Issue link: https://onenorgren.uberflip.com/i/1041773

Contents of this Issue

Navigation

Page 38 of 61

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2019 - 9261a) © 2020 IMI International s.r.o. en 1.6.601.039 01/21 Environmental Specifications Model Number FX5U / FX5UC Operating Ambient Temperature -20 to 55°C (-4 to 131°F), non-freezing (*1) Storage Ambient Temperature -25 to 75°C (-13 to 167°F) Ambient Humidity 5 to 95%RH, non-condensation Ambient Relative Humidity 5 to 95% RH (non-condensing) Vibration Resistance – Frequency Acceleration Half amplitude Sweep count Installed on DIN rail 5 to 8.4 Hz - 1.75 mm 10 times each in X, Y, Z direction (80 min in each direction) 8.4 to 150 Hz 4.9 m/s² - Direct installing 5 to 8.4 Hz - 3.5 mm 8.4 to 150 Hz 9.8 m/s² - Shock Resistance 147 m/s², Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z Noise Durability By noise simulator at noise voltage of 1000 Vp-p, noise width of 1 μs and period of 30 to 100 Hz Grounding Class D grounding (grounding resistance: 100 Ω or less) Common grounding with a heavy electrical system is not allowed. Working Atmosphere Free from corrosive or flammable gas and excessive conductive dust Operating Altitude 0 to 2000 m Installation Location Inside a control panel Overvoltage Category II or less Pollution Degree 2 or less Equipment Class Class 2 4. Limitations when using FX3 Series extension devices • Use a bus conversion module to connect FX3 Series extension modules to a FX5 system. The FX3 Series extension modules can only be connected to the right side of the bus conversion module. Please review the manuals for limitations regarding the number of connectible modules. • Some FX3 intelligent function modules have limitations on the number of connectible modules and the order in which they are connected. AC Power Supply Specifications Model Number FX5U-32M FX5U-64M FX5U-80M FX5UC-32MT FX5UC-64MT FX5UC-96MT Rated Voltage 100 to 240 VAC 24 VDC Allowable Supply Voltage Range 85 to 264 VAC 20.4 to 28.8 VDC Frequency Rating 50/60 Hz - Allowable Instantaneous Power Failure Time Operation can be continued upon occurrence of instanta- neous power failure for 10 ms or less Operation can be continued upon occurrence of instanta- neous power failure for 5 ms or less Power Fuse 250 V, 3.15 A Time- lag fuse 250 V, 5 A Time-lag fuse 125 V, 3.15 A Time-lag fuse Rush Current 25 A max. 5 ms or less/100 VAC; 50 A max. 5 ms or less/200 VAC 30 A max. 5 ms or less/100 VAC 60 A max. 5 ms or less/200 VAC 30 A max. 0.5 ms or less/24 VDC 40 A max. 0.5 ms or less/24 V DC Power Consumption (*1) 30 W 40 W 45 W 8 W 8 W/24 VDC [33 W/24 VDC +20%, -15%] 11 W/24 VDC [36 W/24 VDC +20%, -15%] 5 VDC Power Supply Capacity 900 mA 1100 mA 1100 mA 720 mA 24 VDC Service Power Supply Capacity (*2) When Service Power Supply is Used for Input Circuits 400 mA 600 mA 600 mA 500 mA When External Power Supply is Used for Input Circuits 480 mA 740 mA 770 mA Notes: 1. This value is for when all 24 VDC service power supplies are used in the maximum configuration in which they can be connected to the CPU module. The input current is included. 2. When I/O modules are connected, they consume current from the 24 VDC service power. DC Power Supply Specifications Item FX5U-32M FX5U-64M FX5U-80M Rated Voltage 24 VDC Allowable Supply Voltage Range 16.8 to 28.8 VDC Allowable Instantaneous Power Failure Time Operation can be continued upon occurrence of instantaneous power failure for 5 ms or less. Power Fuse 250V, 3.15 A Time-lag fuse 250V, 5A Time-lag fuse Rush Current 50A max. 0.5 ms or less / 24 VDC 65A max. 2.0 ms or less/24 VDC Power Consumption (*1) 30W 40W 45W 24 VDC Built-in Power Supply Capacity 480 mA (360 mA) (*2) 740 mA (530 mA) (*2) 770 mA (560 mA) (*2) 5 VDC Built-in Power Supply Capacity 900 mA (775 mA) (*2) 1100 mA (975 mA) (*2) Notes: 1. Maximum consumption value when using the maximum configuration connectable to the CPU module. 2. The value in ( ) is capacity of power supply when the supply voltage is 16.8 to 19.2 VDC. Note: The operating ambient temperature is 0 to 55°C (32 to 131°F) for products manufactured before June 2016. Please check manual for precautions when ambient operating temperature is lower than 0C.

Articles in this issue

Archives of this issue

view archives of Datasheets - Mitsubishi Servo Motors Norgren Datasheet