Life Science

Cadent 3 Pump Datasheet - PDS-0034

Issue link: https://onenorgren.uberflip.com/i/851623

Contents of this Issue

Navigation

Page 0 of 3

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2017 Norgren Kloehn, Inc. Cadent 3 Syringe Pump The IMI Norgren Cadent™ 3 is a highly flexible and programmable syringe pump with exceptional precision and accuracy performance in discrete dispense or stable flow modes. This maintenance free pump also offers long life. The IMI Norgren Cadent™ 3 is available with or without its advanced controller in three mechanical resolutions, depending on the needs of your instrument. The pump can be further configured by mating with any of the options from the extensive range of IMI Norgren Syringes and Rotary Valves making the IMI Norgren Cadent™ 3 the most versatile fluid delivery solution for any analytical, diagnostic and biotechnology instrument. Environmental Operating Temperature 36°F to 122°F (2°C to 50°C) Storage Temperature -27°F to 160°F (-33°C to 71°C) Operating Humidity < 80% RH at 5°C - 30°C and < 50% at 31°C - 50°C Noise ⁽¹⁾ < 55 dBA Lifetime ⁽²⁾ > 2 Million cycles (Cadent™ 3) > 5 Million cycles (Cadent™ 3E) [1 cycle = 1 full dispense and aspirate moves] Mechanical Operation Any orientation Mounting Holes Top and bottom Front face Resolutions ⁽⁴⁾ 6K, 12K and 24K increments Performance Speed ⁽¹⁾ 0.0625 - 10,000 half-steps/sec Precision 0.5% CV at 1/10th dispense 0.05% CV at full stroke dispense Accuracy ± 0.3% at 1/10th dispense ± 0.2% at full stroke dispense Flow Rate ⁽¹⁾ Min: 0.008 µL/min (with 50µL syringe) Max: 500 mL/min (with 5mL syringe) Full Dispense Time ⁽¹⁾ Min: 0.6 secs (with 6K resolution) Max: 6400 mins (with 24K resolution) Flow Accuracy ⁽³⁾ ± 1% Linearity R > 0.9999 Electrical Connection ⁽¹⁾ 6 inputs - 2 Analog/Digital, 4 Digital 6 digital outputs Tamper pin Communication Options ⁽¹⁾ RS-232, RS485, CANbus Power Operation 24VDC (± 5% allowance) (with a maximum power ripple of 720mv peak to peak). Power Consumption ⁽¹⁾ 32 watts max; 3 watts idle. Accessory Options Solenoid Valve Options FAS 3/2 Microsol MS (Media Separated) Isolation Valve Rotary Valve Options up to 12 way Syringe Options 50ul to 5ml Compliance REACH & RoHS Compliant CSA and UL Certified CE Compliant Level 1 Robust Syringe Drive Specifications 6/17 PDS-0034 REV. 1 Level 3* Including Advanced Controller *Syringes sold separately Level 2* Including Valve *Syringes sold separately Rotary and Solenoid Valve Options Shown ⁽¹⁾ Rated with IMI advanced controller (Level 3) ⁽²⁾ Tested using DI water and a 1mL syringe at 30 psi ⁽³⁾ Based on a 10KHz sample rate using a 1mL syringe at 1mL/min ⁽⁴⁾ 96K, 192K and 384K increments possible in microstep mode

Articles in this issue

Archives of this issue

view archives of Life Science - Cadent 3 Pump Datasheet - PDS-0034