AIR
PREPARATION
PRODUCTS
4
APP-21
For further information www.norgren.com
Solenoid operated Solenoid operated
*Reduced light intensity at 12V.
P72F Typical performance characteristics
P72F MB002A 4215-02 (1/4) 4214-51 4214-52 54934-08* 12 ... 24 VAC/DC Indicator type
4215-03 (3/8) 54934-02 110/120 VAC Indicator type
54934-01 No indicator
P74F MB004A 4315-02 (3/8) 4314-51 4314-52 54934-08* 12 ... 24 VAC/DC Indicator type
4215-03 (1/2) 54934-02 110/120 VAC Indicator type
4315-04 (3/4) 54934-01 No indicator
Accessories
Exhaust port Quikmount pipe Quikclamp
®
Quikclamp
®
and
silencer adapters (quantity of 1) wall bracket (quantity of 1) Plug with cable gland for 22 mm solenoid
(quantity of 1)
Excelon
®
valves
P72F, P74F Smooth start/Exhaust valves
P72F
Dimensions in inches (mm)
INLET PRESSURE: psig (bar g)
FLOW CHARACTERISTICS
0 5 10 15 20 25 dm
3
/s
AIR FLOW
0 10 20 30 40 50 60 scfm
PRESSURE
DROP
0.8
0.6
0.4
0.2
0
bar
d
10
8
6
4
2
0
psid
44
(3)
91
(6.3)
58
(4.0)
150
(10)
116
(8)
PORT SIZE: 1/4"
0.53 gal (2 liter) downstream volume
SNAP POINT
PERCENTAGE SNAP POINT
0 20 40 60 80 100 120
CHARGE TIME - (S)
OUTLET
PRESSURE
16
12
8
4
0
bar
g
200
160
120
80
40
0
psig
2.60 (66)
0.95
(24)
1.89
(48)
1.77
(45)
3.58
(91)
Pilot port
1/4" exhaust port
2.60 (66)
0.95
(24)
1.89
(48)
4.57
(116)
6.38
(162)
1/4" exhaust port
Indicator type No Indicator